Loading...
045-23 - Puget Sound Energy - Contract Exhibit ADocuSign Envelope ID: 08FD5628-C425-4014-8F4C-CA051AE0930E UST TO CLE R UT SHRUBS / P01 619773 154629 619772 154646 12 40T 2/18 8 SW # T89610 25 B 2/17 — — — — — T 336.4 MCMACSR I U -rl•T. - 619772 EXIST --- MO 1 154654 1 00T GATE EXIST GATE I 13-943 Vol 619767 154639 500 kV 277/480V (ABC) 1535 EXIST Ap O SHOP / 1525 1545 1441 CIRCUIT F ET ADDED: 65' Sq. Footage: /A - EV CHARGING STATION Panel Size: 4 0 AMPS 1435 Heat Type: N/ Est. Demand: 13 KW LRC: 339A • V. Drop: 1. % • Flicker: 2.7 0 500kVA 277/480v Fault Current: 26,100 R/X:0.2 %Z:2.30 SITE PLAN SCALE: 1" = 100' — 1- 5' MIN 3' MIN H Z W W Q OE SW COOK RD / T --- _ I I I � U Z g > 1515 Z Z W H J i (9 Z WWg O WW 1 J oQ Ca Call DLL C) ILL 3' MIN Q Z Lu 3' MIN o 0- <� l­-°d� 5'MIN w00 n n / \ I Q i U H �Q� i 5' MIN - < 5' MIN rn Of rn C) 0 Y UQ 10- MIN UQ o Q Q ROAD OR PARKING AREA L — MINUMUM CLEARANCES FOR PSE EQUIPMENT (V01) SCALE: NONE Trench and backfill requirements for primary electric line extension trenches (No PSE gas) - A 12" layer of sand, 5/8" minus, or clean shading is required when excavated native material contains rocks up to 10" in diameter. - A 6" layer of sand, 5/8" minus, or clean shading is allowed when excavated native material contains rocks no larger than 8" in diameter. Excavated Dirt Pile ROADSIDE 18" 24" Min \\\\\\\\\\\ Final Grade Typical To Excavated Dirt Pile \i rBackfill for DB 120 Conduit/Direct Buried Cable 36 �� 12" Min (No Rocks over 10" Diameter) 48„ % Separation Max Min �� Cover \� 6" or 12" of sand, 5/8" minus \� or clean backfill shading 3" of sand, 5/8" minus, or clean backfill bedding Phone & TV Primary Power Cable Direct Buried or in PSE provided DB120 Grade Conduit CUSTOMER -SUPPLIED TRENCH FOR PRIMARY CABLE(P01 TO V01 SCALE: NONE LUMSDEN RD SITE SPECIFIC NOTES P01 GRID #619773-154629: -PSE OWNED 65' TRANSMISSION POLE TO REMAIN -INST 1/0 AL 3PH PRI TERM ON FG ARM -INST L/B C/O & SURGE ARRESTER FUSE @40T -INST SW #T89610 -INST (3) STIRRUPS & HOT CLAMPS -INST 4" PRI RISER ON S/O BRACKETS, (ACTUAL= ') -INST CABLE #'S AO-AFK878, BO-AFK879, CO-AFK880 V01 GRID #619767-154639: -INST TX 7' X 4' W/ 60" X 24" ACCESS W/ 8' SQ COVER -SET 500KVA, 277/480V PM XFMR -INST (3) 1/0 CS PRI TERMS -INST CABLE #'S AO-AFK878, BO-AFK879, CO-AFK880 -INST GRID #619767-154639 -CONNECT & TAG CUST INSTALLED UG SVC CONDUCTORS (2 RUNS OF 4/0 UG WIRE) SPAN SPECIFIC NOTES 6043.1000, TSU3L1 F 6042.1000, RIS4CSS 6045.5000, PM3P15M MID:6259250 6041.1000, ELB10J P01-V01: -INST 14" DB120 CONDUIT ±65', (ACTUAL= ') IN CUSTOMER PROVIDED TRENCH -INST (3) 1/0 AL SOL JACKETED PRI CABLE, ±100', (ACTUAL= ') 2-36(60') DED FAC 2-55(60') DED FAC 3-19B "NOTE: CITY OF PORT ORCHARD WILL BE RESPONSIBLE 100% ALL EXCAVATION & RESTORATION. CUST IS 100% RESPONSIBLE TO CLEAR -OUT SHRUBS AT P01. PRE -CON WILL BE REQUIRED BEFORE ANY EXCAVATION ON -SITE." FOREMAN MUST FILL IN CABLE #: AFK878 CABLE #: AFK879 CABLE #: AFK880 MANUFACTURER- MANUFACTURER- MANUFACTURER- YEAR MANUFACT: YEAR MANUFACT: YEAR MANUFACT: COMPOUND: COMPOUND: COMPOUND: Primary Cable & Conduit Table (Foreman to Complete) POSSIBLE CUSTOMER ENTRY LOCATION I I PSE FROM P01---// CABLE INSTALLATION DIAGRAM R Not to scale P01 619773 154629 40T SW #T89610 90° 2/17 PULL F=91lbs R=358lbs 90, A 619767 V01 154639 500 kVA 277/480V (ABC) CONDUIT DIAGRAM SCALE: NONE TRANSFORMER INSTALLATION (PM) Installed at site: Vol Grid Number: 619767-154639 kVA Rating: 500kVA 277/480y Material ID#: 6259250 Foreman to redline the following information Company ID#: Primary phase connected to: Tested Secondary Voltage POWER GENERAL NOTES - COMMERCIAL PROJECT 1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. 2. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. CUSTOMER NOTES Customer is responsible for all trenching, select backfill, compaction & restoration per Puget Sound Energy Standards & Local Municipality (See PSE Electric Service Handbook for more details). 1. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. 2. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. 3. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. 4. Roads shall be paved or have a compacted , crushed rock base in place. 5. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. 6. All work is to be done in accordance with local municipal and county permit requirements as applicable. 7. Inclement weather conditions may cause delays in construction times and dates. 8. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. 9. EROSION & SEDIMENT CONTROL: Erosion & sediment control shall be per PSE standard practice 0150.3200 techniques for temporary erosion & sediment control & any additional local jurisdiction requirements. (Local jurisdiction may have additional requirements including notes detailing where erosion or sediment control structures are to be installed, cross section details of the typical erosion structures, & special requirements for work in sensitive areas.) 10. Customer is required to have meter inspected and approved by L&I/City prior to construction. LOCATION PSE PROVIDE CONDUIT PRIMARY CABLE QTY OF LUBE (gal.) AS BUILT INFORMATION Design Actual TYPE BENDS PULL PULL Cable Design Actual CABLE NUMBERS MANUFACTURING INFORMATION From To Size Qty Length Length (Ibs) Rev Size Length Length (in) (ft) (ft) DB120 HDPE SCH 80 90° 45° 22° 11 ° (Ibs) (ft) (ft) A B C Manufacturer Compound Year Design As Built Actual Amount Installed (Conduit &Cable) P01 V01 4" 1 65' X 2 91 358 1/0 100, AFK878 AFK879 AFK880 1 GAL CITY OF PORT ORCHARD IS RESPONSIBLITLY TO PROVIDE GUARD POST 5' S'MAPAINTED MAX X YELLOW 5' N MIN 9 3'-6• MAX MAX LENGTH 64r MIN MIN l TYPICAL 5 PAD 8 5 MAX XFMR MAX FRONT CONCRETE 7-6• 5 GUARD MAX POSTS MIN 3 5' MAX �I 5• i. MIN -- X MAX MAX GUARD POST INSTALLATION GUARD POST LOCATIONS The following styles of guard posts are approved for Puget Sound Energy transformers: - 6 ft x 4 in. diameter Schedule 40 or better galvanized steel pipe filled with concrete. The concrete shall have a. minimum compressive strength of 3000 psi after 28 days - The exposed portion of the post shall be painted traffic yellow. - 6 It x 9 in. diameter precast steel -reinforced concrete post. Available from Utility Vault Company, Auburn, WA; or Hanson Inc., Tacoma, WA. The exposed portion of the post shall be painted traffic yellow. GUARD POST INSTALLATION REQ FOR V01 Not to scale 0700.1600-03 8'-0" 8'-0" 8" or 10'-0" 4'-2" 3'-6" 7'-0" i T-0" TOP VIEW 0111, 000 SIDE VIEW Excavation - 20 cubic yards VAULT & EXCAVATION DETAIL (V01) Not to scale 6045.5000 CIRCUIT LOADING TABLE CIRCUIT: EPO-12 AS OF 4/17/2023 A PHASE B PHASE C PHASE EXIST. PEAK LOAD 123 172 152 EST. NEW LOAD 12 12 12 TOTAL 135 183 163 FOREMAN (CHECK BOX WHEN COMPLETED) ❑ PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. ❑ Grid, Cable, and Switch numbers INSTALLED & VERIFIED. ❑ Field Changes RED -LINED on As -built. ❑ Material VERIFIED and CHANGES noted on Paperwork. ❑ Total PRIMARY Cable noted on As -built. ❑ Company ID#'s RECORDED in correct location on As -built. ❑ Indicate correct FUSE SIZE on As -built & VERIFY proper PHASE. ❑ Deviations noted on the As -built and their reason. ❑ I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. Quadrant Foreman's Signature 4' x 4' Work Pit Field Face \ (Pole Butt Must Be Exposed) Print Name Date Quadrant 5" Min Climbing Space / 619772 619774 Standoff Bracket Conduit \ 1546047619773 154645 15" Min Length Conduit Clamp — Z 619772 154629 2/17 154646 2/18 \ P01 25 kVA (B) 2" 6" Crushed 4'-6" Rock Direction of Vehicular Traffic Climbing Space Zoad Face, PROJECT PHASE NOTIF# ORDER# PWR Superior Perm. Service Metering Removal Temporary Job Order 513819438 105102908 513965511 104352382 3002208608 N/A N/A N/A N/A N/A N/A GAS Distribution Service Stubs HP Svc/MSA N/A N/A N/A N/A N/A N/A CABLE TV PHONE // Project Manager Contact Information: Manager: Victor Ibarra Cell Phone: 425-429-4574 TOP VIEW E-Mail: victor.ibarra@pse.com CONDUIT RISER PLACEMENT DETAIL (P01) PRIMARY ONE -LINE & UG MAP: BEFORE PSE Locates Required NO SCALE: NONE SCALE: NONE Customer Locates Required YES 0 / is JOB SITE / A Ar 30: SW R�\25T 125T % T86112 A EPO 100T c 12 WE 17 C 1-94 25T 13 1003; ' 30 (CROSS COUNTR I r- I- 3 0: n o 3 0: ...............A 1g -: .... 3Sb : • '3;: ..........40T 30 30 13-792g.... B. ..Iii:E:: 13-707 OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILE 619773 POI 154629 40T 619774 SW #T89610 154645 2/17 6197727 � 619772 154604 I 154646 2/18 2/16 A 25 kVA (B) AO—AFK878 619767 Vol BO—AFK879 15-4639 CO—AFK880 500 kVA 277/480V (ABC) L_ PRIMARY ONE -LINE & UG MAP: AFTER SCALE: NONE Vicinity Map JOB SITE 34 27 5� - Owner / Develoner Contact Info V t 0 O 00 City of Port Orchard 216 Prospect St Port Orchard, WA 98366 ATTN: Tony Lang 360-876-7019 office For contacts below dial 1-888-CALL PSE (225-5773) CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES Outages Required NO Flagging Required YES REAL ESTATE/EASEMENT ROW REVIEW / EASEMENT PERMIT N/A 3 FUNCTION CONTACT PHONE NO DATE 2 PROJECT MGR Victor Ibarra 425-429-4574 4/17/23 1 ENGR - POWER Helene Sparks 360-475-7001 4/17/23 REV# DATE BY DESCRIPTION ENGR - GAS N/A N/A N/A COUNTY KITSAP Emer Sect N/A Gas Wk Ctr N/A POWER WK CTR QSSPE DRAWN BY Helene Sparks 360-475-7001 4/17/23 CHECKED BY 1/4 SEC SE SEC34 T24 R1 E OP MAP N/A PLAT MAP N/A APPROVED BY 425-495-0703 5 2/2023 FOREMAN #1 NO (POWER) 2401E136 -[--U-MAP OH CKT MAP 2401E136 UG CKT MAP 2401E135 CIRCUIT NO EPO-12 FOREMAN #2 MAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES N/A N/A N/A N/A CONTACT N/A N/A N/A N/A PHONE# N/A N/A N/A N/A INCIDENT MAOP PUGET CITY OF PORT ORCHARD EV STATION N/A N/A SOUND Elect Order COMMERCIAL INST 30 OH-UG PRI L/E GaNOrder 105102 08 ENERGY 1535 VIVIAN CT # EV CHRGERS PORT ORCHARD, WA 98367 SCALE FGE PSE AS NOTED 1/1