Loading...
PO Marina PS - Addendum 1 PlansCONTRACTOR DESIGNED LANDINGS AND WETWELL CATWALK NOTES: 1. SHALL BE DESIGNED TO SUPPORT A 60 PSF LIVE LOAD OR A 300 LB LIVE CONCENTRATED LOAD. 2. SUPPORTS AND FASTENERS SHALL BE 316 STAINLESS STEEL 9'-01 r TOP OF SPREAD FOOTING, EL. 12.17' TYP. 301 PROPOSED SPREAD S703 FOOTING WET WELL TO BE REHABILITATED TOP OF STEM WALL, EL. 16.50' TYP. 2'-0" CONTRACTOR DESIGNED WETWELL CATWALK 12 EXTEND WALLS VERTICALLY TO EL 15.5', TYP. 31 _0" FRP GRATING, TYP. PROPOSED TOP OF WETWELL CATWALK, EL 7.5', TYP. PROPOSEDLADDER ACCESS HATCH OPENING OUTLINE (ABOVE) 3'-0" 0 VENT PENETRATION (ABOVE) A B TOP OF STEM WALL TO MATCH 0 Sl 07,r TOP OF STEM WALL TO MATCH S108 SLOPE OF ADA RAMP RISE/RUN OF STAIR STEPS Q'\/' v -\/' 11/' N TOP OF STEM WALL, (EL. 15.83' TYP. BEAM - WALL CONNECTION, TYP. 506 S705 1:1 PROPOSED TOP OF WALL, EL 15.5', TYP. 30'-4" DRY WELL ACCESS ❑ HATCH OPENING OUTLINE (ABOVE) MULTI -USE FACILITY 11'-6" SPREAD FOOTING UNTIL 301 1'-0", TYP., FULL PERIMETER ANCHOR QEA RETAINING101, 5703 WALL, SEE DWG NO. L001 V-0", TYP., FULL PERIMETER 2'-2", TYP., FULL PERIMETER 10'-6" .o vz 1 3 � ,0 1 51'-8" 2'-4" 8'-2" C1� SUMP BELOW _ TOP OF STEM WALL, EL. 16.50' TYP. PROPOSED CONCRETE 309 PEDESTAL TO BEAR ON STRUCTURAL FILL S704 PROPOSED 3 TON CAPACITY TRAVELING MONORAIL, S15X42.9 W/ C10X15.3 PROPOSED MONORAIL - BEAM CONNECTION PER MANUFACTURER, TYP. PROPOSED STATIONARY BEAM, W10X26, TYP. OF 2 SEE DWG NO. M302 FOR ADDITIONAL REINFORCING FOR PIPE BEND THIS AREA PROPOSED PUMP STATION DRY WELL ENTRANCE 4" 4" 4" MI STD HOOK DEVELOPED #8 #9 #9 #8 INTO SLAB VERTICAL BAR DETAIL 1 STAIR ACCESS HATCH OPENING OUTLINE (ABOVE) VERTICAL BAR DETAIL 1 O.F. RST VENT PENETRATION L J (ABOVE) 1 TOP OF WALL 1'-6" TYP. EL. 10.50', TYP I CONCRETE L INTERSECTION, S 0 2 ,i TYP. 0 GV J w 0 a m a LOWER PLATFORM w LADDER 2'-6" 4'-6" - 3'-0" MI STD HOOK DEVELOPED INTO SLAB VERTICAL BAR DETAIL 2 N TS N TS #8 VERTICALLY CENTERED 519„ BETWEEN TYPICAL O.F. 1'-0" RST. TOTAL RST = #8 @ 6" O.C., O.F., TYP doft C S109 g"2 FRP GRATING, TYP. UPPER PLATFORM 5'-9" LADDER 8'-0" ACCESS HATCH OPENING OUTLINE (ABOVE) 21-311 m PROPOSED EMERGENCY CONTRACTOR DESIGNED 4'-6" D W (2) #6 x 6'-0" VERTICALLY CENTERED BETWEEN STORAGE LANDING, TYP. TYPICAL O.F. RST FOR 4" TOP OF LANDING, TYP., LOWER STRUCTURE A SPACING, TYP. 8'-0" EL. -3.06 PLATFORM CONTRACTOR DESIGNED LADDER NJ 2' 3" LANDING, TYP. � n STRUCTURE X /) BASE SLAB 3'-0" 1'-6" ACCESS HATCH TYP. o OPENING OUTLINE TYP CONCRETE 302 (ABOVE) CORNER RST. S702 VERTICAL BAR DETAIL 1 O.F. RST PROPOSED SUMP IUPPER PLATFORM , 306 PUMP PIPE LADDER 5703 EXISTING PROPOSED PUMP EMERGENCY ®r STATION STORAGE MULTI -USE CONCRETE MODIFICATIONS STRUCTURE FACILITY 301 RETAINING WALL, SPREAD S703 SEE DETAIL 3 ON FOOTING DWG NO. L007 A B (ANCHOR QEA) S107 S108 PUMP STATION, VALVE VAULT, AND EMERGENCY STORAGE WALL PLANS y" = 1'-0„ 4 #8 CENTERED BETWEEN TYPICAL O.F. RST. TOTAL 5'-9" RST = #8 @ 6" O.C., O.F., TYP 5'-9" SIGNED. 0610212023 of W cc 2i o m o 0 o z a_ O a Of (n _ o z z w z W � 1 J U Lu (> z o Z wo 0 o 0 Q SEE LANDSCAPING coC"i cocli m U- � PLANS FOR SPREAD 04 ,� o z 0 FOOTING EXTENTS = = o w =) w a U W � w co o 0 0 v¢ O c'7 N N O c\j Q U a U o U � W z W as Lu � SCALE: SHOWN oil ill 2 DRAWING IS FULL SCALE WHEN BAR MEASURES 2" DWG NO.: SHEET NO.: S102 58 123 HSS 6x6x%6" ROOF OVERHANG COLUMN, TYP. A S107 36'-8" 19'-2" OUTLINE OF ROOF, TYP. 2'-2" 3'-4" l'-9" '-0' V-10" 3'-4" 4'-6" EXTERIOR CONCRETE I WALL, TYP. I D104 L106 D105 302 CONCRETE 5702 INTERSECTION, TYP. EL 30.00', TOP OF CONCRETE WALL 3'-0" WALL PIER, TYP. OF 4, RST DETAIL 2'-6" L104 THIS SHEET 3'_2" 42'-8" 71 C 5-0" L103 S109 1'-8" 1'-4" D102 O 308 CONCRETE S702 LINTEL, TYP. 306 CONCRETE WALL S702 PENETRATION, TYP. 3'-0" 2'-6" L105 DRY WELL ENTRANCE n diZZ ll= II� 8" ALL FF EL '16.50', TYP. WALLS, TYP. � ODOR CJ7� CONTROL ROOM 9'-11" Z21 of NOTE: 1. ACCESS HATCH CALLOUTS SHOWN ON ACCESS PLAN DWG NO. S105 2. BATHROOM DETAILS SHOWN ON DWG NO. A04.01 AND A25.01 3. TOP OF WALL ELEVATIONS SHOWN ON DWG. NO S106 4. SEE DWG NO. S105 FOR ACCESS DETAILS 5. SEE ACCESS PLAN ON DWG NO. S105 FOR BUILDING AND SITE TRANSITIONS. 6. SEE MECHANICAL AND ELECTRICAL PLANS FOR ADDITIONAL UNDER/IN SLAB PIPING AND CONDUIT. 7. SEE DWG NO. A105 FOR DOOR SCHEDULE. 8. SEE 300 FOR GENERAL STRUCTURAL NOTES. TYP. A S107 ADA RESTROOM 16 KIP PUMP 9'-0" OUTLINE OF CONCRETE PEDEST SUPPORTING SLAB 1'-0" L107 I 3'-4" I 5'-8" I I D1 401 CMU KNOCKOUT S704 WALL EMERGENCY DIESEL -DRIVEN PUMP ROOM INTERIOR CONCRETE WALL, TYP. 1 CONCRETE L302 INTERSECTION, TYP. 5702 *ELECTRICAL ROOM (30§6 CONCRETE W PENETRATION,1 10'-4" 3'-0" 2'-10" 1' 4" L108 3'-6" 2'-8" L109 3'-0" 1'-4" �26-0" 4'-0" I D 103 3'-4" 8'-011 9'_811 COLOR LEGEND EQUIPMENT PAD CONCRETE WALL WALL PIER LOUVER ROOF OUTLINE 1'-9" - SLAB OPENING 306 S703 4'-10" TOP OF ACCESS HATCH, EL. 16.50', TYP. 36-10" 21'-0" MULTI -USE FACILITY FLOOR AND EMERGENCY STORAGE PLAN y" 4 STAIRWAY ACCESS TO BELOW -GRADE PUMP STATION TOP OF EMERGENCY STORAGE ACCESS SLAB, 1'-6" EL. 16.50' we] TOP OF ACCESS HATCH, EL. 16.50', TYP. EMERGENCY STORAGE 403 VENTILATION LIGHT POLE S7o4 SIGNED. 0610212023 H cn z Z w � oa J � Z as Va OW 0 C� _ �p a � O 0­4 W C� P-4� J _a w `L' V m o a0 U. W V� �>. V rs' Z W J o �a � a � W oa W uj � Y uj c� 0 Z a_ 0 a(n W o z W W W o U' z Lu LENGTH VARIES PER PLAN o 6" O.C. @ 12" O.C. MAX M O N co O N m offW U- Of a o ENDS, BETWEEN ENDS #4 VERTS wui oLo I TYP. O o #3 HOOPS @ 6" O.C. FULL .a Q o • • a a • . 8,TYP. OF WALL a M M MHEIGHT U () � o 0 U WALL PIER BAR DETAIL PLAN VIEW W NTS SCALE: SHOWN Q l" 2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" DWG NO.: SHEET NO.: S104 60 123 NOTE: 1. ALL EXTERIOR ACCESS WALKWAYS TO HAVE 2% SLOPE AWAY FROM MULTI -USE FACILITY 61-611 TOP CON( PLANTER EL. 2'-0" 10'-0" TYP. HSS 6x6x%6" ROOF OVERHANG COLUMN, TYP. TOP SPREAD FOOTING, TYP. 4'-0" 5'-0" 44'-0,' 26'-0" TOP STEM WALL, TYP. 4'-2" 2% TYP. 12'-11" ELEVATED BENCH TO COVERINTAKE 8L � 4'-4" ~ 6'-2" DRY WELL VENTILATION LOCATION A S107 2% TYP. p 10" 5'-0" A f%f%CCC DI A AI Y" = 1'-0" 4 ADA RAMP OP STEM WALL, _ TYP. PROPOSED GUARDRAIL, TYP. WALKWAY ACCESS, DRYWELL/ EMERGENCY TOP OF EMERGENCY STORAGE, EL. 12.50 TYP. c S109 TOP OF STEM WALL, EL. 16.50 TYP. . 5'-9" -, - 34'-1" -, - 6'-0" RH2 SIGNED. 0610212023 I"r Z Z w � J a � O c/) V � c/) W Oz L) v �o a O� O � � V a LL ►--r V Z Lu C/) J D a gC2 c� 0 o Z a_ O a(n o z W W W W o Z_ 0 0 0 0 Q co oN M04 N m of O W a co N cd N U- 0 W uw (n o a > N - > w � o w 0 � 0 Q� a co (V M CV w O N ¢O C) o CD 0 c w � o a OZ z w w ¢ SCALE: SHOWN SEE LANDSCAPING Dll 2 DRAWING IS FULL SCALE WHEN PLANS FOR SPREAD FOOTING EXTENTS BAR MEASURES2" DWG NO.: SHEET NO.: S105 61 123 RH2 p,T S~ Saye + GISTS i `SI w M * V� J O ~ 0 �--I O Z O � V O � Q V� ~ �i W J W a � Y 0 0 0 c� 0 0 U W W V/ J '^ o w z z z � W W o CC c� z z Wo 0 o Q CD of Of N ZO 0 N N 0 W a W (n � > U N W W w � � � o 0 0 - � O Q� a N W O N O co co CO 0 m Y w � z W �a * NUMBER OF LAMPS PER FIXTURE oll ill 2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" DWG NO.: SHEET NO.: �/1231 E023 115 ELECTRICAL EQUIPMENT AND INSTRUMENTATION SCHEDULE PANEL SCHEDULE L ITEM DESCRIPTION 0 MANUFACTURER MODEL N0. N0. LOCATION: PUMP STATION 208/120 VOLTS 3� 4 WIRE MAIN SERVICE DISCONNECT SWITCH NEMA 1 ENCLOSURE, L SERVING: PUMP STATION LOADS 125 AMP MAIN HEAVY DUTY BREAKER, SERVICE ENTRA C RONIC OA TRIP, 800 AMP, 480 VOLT, 3� 42 KAIC WITHSTAND, CIRCUIT SIEMENS SHMD6 OR EQUAL CIRCUIT DESCRIPTION KVA AMP AMP KVA CIRCUIT DESCRIPTION BREAKER SWITCH. FLEX HANDLE OPERATOR MOUNTED ON SIDE GENERATOR LOAD CENTER, "G" 4.10 100 1 1_12 20 0.34 ELECTRICAL ROOM LIGHTS OF ENCLOSURE. - 3P 3 4 20 0.17 ODOR CONTROL ROOM LIGHTS B AUTOMATIC TRANSFER SWITCH -NEMA 1 ENCLOSURE, 800 AMP, TH 480 VOLT, 3�, 3 POLE, 42 KAIC WITHSTAND. SEE SPECIFICATIONS SEE SPECIFICATIONS - 3P 5 6 20 0.56 EMERGENCY PUMP ROOM LIGHTS ov AS& GENERATOR DISCONNECT SWITCH -NEMA 4X SS ENCLOSURE, DRY WELL ENTRANCE LIGHTS 0.16 20 7 8 20 0.20 RESTROOM LIGHT, FAN, AND MOTORIZED LOUVER © HEAVY DUTY BREAKER, ELECTRONIC TRIP, 800 AMP, 480 VOLT, SIEMENS SHMD6 OR EQUAL ALTERNATIVE STAIRWAY LIGHTS 0.17 20 9 10 20 0.62 DRY WELL LIGHTS 3� 42 KAIC WITHSTAND, CIRCUIT BREAKER SWITCH. FLEX HANDLE OPERATOR MOUNTED ON SIDE OF ENCLOSURE. TELEMETRY PANEL, "RTU" 0.50 20 11 12 20 0.17 EXTERIOR LIGHTS 57189 GENERATOR DOCKING STATION - 800 AMP, 2 PARALLEL 400 VENTILATION POLE SITE LIGHT 0.18 20 13 14 20 0.54 ELECTRICAL ROOM/ODOR CONTROL ROOM RECEPTACLES GNAL AMP SERIES 16 CAMLOC CONNECTORS PER PHASE, NEUTRAL, GDS-085W-LM-AI EMERGENCY PUMP ROOM RECEPTACLES 0.54 20 15 16 20 0.18 RESTROOM RECEPTACLE AND GROUND. WITH 2 WIRE START TERMINALS, STAINLESS STEEL TRYSTAR OR EQUAL CONSTRUCTION. DRY WELL RECEPTACLES 0.54 20 17 18 20 0.54 EXTERIOR RECEPTACLES 1 SIGNED. 0610212023 cn O DISTRIBUTION PANEL - 480/277V, 3�, 4W, NEMA 1 ENCLOSURE, SIEMENS TYPE P5 OR EQUAL EXTERIOR RECEPTACLES 2 0.36 20 19 20 20 0.18 VALVE VAULT SUMP PUMP 1 DEDICATED RECEPTACLE 800A MAIN CIRCUIT BREAKER, COPPER BUSSING. VALVE VAULT SUMP PUMP 2 DEDICATED RECEPTACLE 0.18 20 21 22 20 0.18 DRY WELL SUMP PUMP 1 DEDICATED RECEPTACLE LIGHTING TRANSFORMER - 30 KVA DRY TYPE, 480-120/208V, P030KBKF OR DRY WELL SUMP PUMP 2 DEDICATED RECEPTACLE 0.18 20 23 24 20 0.18 ALTERNATIVE STAIRWAY SUMP PUMP DEDICATED RECEPTACLE OF 3�, CONSTRUCTION SHALL CONSIST OF COPPER WINDINGS, HAMMOND EQUAL PROVIDE WITH WALL MOUNT BRACKETS. MINI SPLIT UNIT 1 3.00 30 25 26 30 3.00 MINI SPLIT UNIT 2 © LIGHTING PANEL - 208/120V 3�, 4W, NEMA 1 ENCLOSURE, SIEMENS TYPE P1 OR EQUAL - 2P 27 28 2P - COPPER BUSSING. DRAIN VALVE ACTUATOR 0.50 20 29 30 20 0.18 WET WELL LIGHTS MANUAL TRANSFER SWITCH - 800 AMP, 600 VOLT HEAVY DUTY DOUBLE -THROW NON -FUSIBLE SAFETY SWITCH, NEMA 3R DTNF3675 OR VENTILATION CONTROL PANEL, "VCP" 1.33 30 31 32 20 0.10 FIRE ALARM CONTROL PANEL OH ENCLOSURE. HANDLE UP POSITION SHALL BE FOR PERMANENT SIEMENS EQUAL SPARE - 20 33 34 20 0.10 EMERGENCY PUMP BATTERY CHARGER ON -SITE GENERATOR, HANDLE DOWN POSITION SHALL BE FOR PORTABLE GENERATOR. SPARE - 20 35 36 20 1.50 EMERGENCY PUMP BLOCK HEATER INTRUSION ALARM SWITCH -CONTRACTOR SHALL SELECT HEAVY DUTY TYPE SPARE - 20 37 38 20 - SPARE OI ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING SQUARED C, CLASS 9007 OR SPARE - 20 39 40 20 - SPARE CONFIGURATION EQUAL INTRUSION ALARM SWITCH -CONTRACTOR SHALL SELECT HAZARDOUS SPARE - 20 41 42 20 - SPARE O ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING ALLEN-BRADLEY LOCATION 802XR CONFIGURATION. SWITCH SHALL BE A HAZARDOUS LOCATION SERIES CONNECTION LOAD: DEMAND: LIGHTING 8c RECEPTACLE LOAD DEMAND LOAD: SEALED SWITCH RATED FOR CLASS 1 DIVISION 1 LOCATIONS. 20.5 KVA 56.9 AMPS 20.5 KVA 56.9 AMPS O FLOOD SWITCH - N.O. REED TYPE FLOAT SWITCH, 20 VA. SEE OMEGA LVN-20 OR EQUAL DWG N0. E018 FOR DETAILS. GFCI CIRCUIT BREAKER L FLOAT SWITCH SEE SPECIFICATIONS SEE SPECIFICATIONS W OM SUBMERSIBLE PT LEVEL TRANSDUCER SEE SPECIFICATIONS SEE SPECIFICATIONS ON RADAR LEVEL TRANSMITTER SEE SPECIFICATIONS SEE SPECIFICATIONS OO FLOW METER SEE SPECIFICATIONS SEE SPECIFICATIONS W WALL MOUNTED HEATING THERMOSTAT - 24V, SPST, RANGE: 40° TH6110D1005/U OR PANEL SCHEDULE L ITEM DESCRIPTION 0 MANUFACTURER MODEL N0. N0. LOCATION: PUMP STATION 208/120 VOLTS 3� 4 WIRE MAIN SERVICE DISCONNECT SWITCH NEMA 1 ENCLOSURE, L SERVING: PUMP STATION LOADS 125 AMP MAIN HEAVY DUTY BREAKER, SERVICE ENTRA C RONIC OA TRIP, 800 AMP, 480 VOLT, 3� 42 KAIC WITHSTAND, CIRCUIT SIEMENS SHMD6 OR EQUAL CIRCUIT DESCRIPTION KVA AMP AMP KVA CIRCUIT DESCRIPTION BREAKER SWITCH. FLEX HANDLE OPERATOR MOUNTED ON SIDE GENERATOR LOAD CENTER, "G" 4.10 100 1 1_12 20 0.34 ELECTRICAL ROOM LIGHTS OF ENCLOSURE. - 3P 3 4 20 0.17 ODOR CONTROL ROOM LIGHTS B AUTOMATIC TRANSFER SWITCH -NEMA 1 ENCLOSURE, 800 AMP, TH 480 VOLT, 3�, 3 POLE, 42 KAIC WITHSTAND. SEE SPECIFICATIONS SEE SPECIFICATIONS - 3P 5 6 20 0.56 EMERGENCY PUMP ROOM LIGHTS ov AS& GENERATOR DISCONNECT SWITCH -NEMA 4X SS ENCLOSURE, DRY WELL ENTRANCE LIGHTS 0.16 20 7 8 20 0.20 RESTROOM LIGHT, FAN, AND MOTORIZED LOUVER © HEAVY DUTY BREAKER, ELECTRONIC TRIP, 800 AMP, 480 VOLT, SIEMENS SHMD6 OR EQUAL ALTERNATIVE STAIRWAY LIGHTS 0.17 20 9 10 20 0.62 DRY WELL LIGHTS 3� 42 KAIC WITHSTAND, CIRCUIT BREAKER SWITCH. FLEX HANDLE OPERATOR MOUNTED ON SIDE OF ENCLOSURE. TELEMETRY PANEL, "RTU" 0.50 20 11 12 20 0.17 EXTERIOR LIGHTS 57189 GENERATOR DOCKING STATION - 800 AMP, 2 PARALLEL 400 VENTILATION POLE SITE LIGHT 0.18 20 13 14 20 0.54 ELECTRICAL ROOM/ODOR CONTROL ROOM RECEPTACLES GNAL AMP SERIES 16 CAMLOC CONNECTORS PER PHASE, NEUTRAL, GDS-085W-LM-AI EMERGENCY PUMP ROOM RECEPTACLES 0.54 20 15 16 20 0.18 RESTROOM RECEPTACLE AND GROUND. WITH 2 WIRE START TERMINALS, STAINLESS STEEL TRYSTAR OR EQUAL CONSTRUCTION. DRY WELL RECEPTACLES 0.54 20 17 18 20 0.54 EXTERIOR RECEPTACLES 1 SIGNED. 0610212023 cn O DISTRIBUTION PANEL - 480/277V, 3�, 4W, NEMA 1 ENCLOSURE, SIEMENS TYPE P5 OR EQUAL EXTERIOR RECEPTACLES 2 0.36 20 19 20 20 0.18 VALVE VAULT SUMP PUMP 1 DEDICATED RECEPTACLE 800A MAIN CIRCUIT BREAKER, COPPER BUSSING. VALVE VAULT SUMP PUMP 2 DEDICATED RECEPTACLE 0.18 20 21 22 20 0.18 DRY WELL SUMP PUMP 1 DEDICATED RECEPTACLE LIGHTING TRANSFORMER - 30 KVA DRY TYPE, 480-120/208V, P030KBKF OR DRY WELL SUMP PUMP 2 DEDICATED RECEPTACLE 0.18 20 23 24 20 0.18 ALTERNATIVE STAIRWAY SUMP PUMP DEDICATED RECEPTACLE OF 3�, CONSTRUCTION SHALL CONSIST OF COPPER WINDINGS, HAMMOND EQUAL PROVIDE WITH WALL MOUNT BRACKETS. MINI SPLIT UNIT 1 3.00 30 25 26 30 3.00 MINI SPLIT UNIT 2 © LIGHTING PANEL - 208/120V 3�, 4W, NEMA 1 ENCLOSURE, SIEMENS TYPE P1 OR EQUAL - 2P 27 28 2P - COPPER BUSSING. DRAIN VALVE ACTUATOR 0.50 20 29 30 20 0.18 WET WELL LIGHTS MANUAL TRANSFER SWITCH - 800 AMP, 600 VOLT HEAVY DUTY DOUBLE -THROW NON -FUSIBLE SAFETY SWITCH, NEMA 3R DTNF3675 OR VENTILATION CONTROL PANEL, "VCP" 1.33 30 31 32 20 0.10 FIRE ALARM CONTROL PANEL OH ENCLOSURE. HANDLE UP POSITION SHALL BE FOR PERMANENT SIEMENS EQUAL SPARE - 20 33 34 20 0.10 EMERGENCY PUMP BATTERY CHARGER ON -SITE GENERATOR, HANDLE DOWN POSITION SHALL BE FOR PORTABLE GENERATOR. SPARE - 20 35 36 20 1.50 EMERGENCY PUMP BLOCK HEATER INTRUSION ALARM SWITCH -CONTRACTOR SHALL SELECT HEAVY DUTY TYPE SPARE - 20 37 38 20 - SPARE OI ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING SQUARED C, CLASS 9007 OR SPARE - 20 39 40 20 - SPARE CONFIGURATION EQUAL INTRUSION ALARM SWITCH -CONTRACTOR SHALL SELECT HAZARDOUS SPARE - 20 41 42 20 - SPARE O ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING ALLEN-BRADLEY LOCATION 802XR CONFIGURATION. SWITCH SHALL BE A HAZARDOUS LOCATION SERIES CONNECTION LOAD: DEMAND: LIGHTING 8c RECEPTACLE LOAD DEMAND LOAD: SEALED SWITCH RATED FOR CLASS 1 DIVISION 1 LOCATIONS. 20.5 KVA 56.9 AMPS 20.5 KVA 56.9 AMPS O FLOOD SWITCH - N.O. REED TYPE FLOAT SWITCH, 20 VA. SEE OMEGA LVN-20 OR EQUAL DWG N0. E018 FOR DETAILS. GFCI CIRCUIT BREAKER L FLOAT SWITCH SEE SPECIFICATIONS SEE SPECIFICATIONS W OM SUBMERSIBLE PT LEVEL TRANSDUCER SEE SPECIFICATIONS SEE SPECIFICATIONS ON RADAR LEVEL TRANSMITTER SEE SPECIFICATIONS SEE SPECIFICATIONS OO FLOW METER SEE SPECIFICATIONS SEE SPECIFICATIONS W WALL MOUNTED HEATING THERMOSTAT - 24V, SPST, RANGE: 40° TH6110D1005/U OR N0. LOCATION: GENERATOR 208/120 VOLTS 3� 4 WIRE LIGHTING FIXTURE SCHEDULE ABOVE FLOOR. ELECTRICAL HEATER WITH UNIVERSAL MOUNTING BRACKET - 5KW, 480V, THREE PHASE, WITH 24V CONTROL NAME QTY. CATALOG N0. ® TRANSFORMER AND POWER CONTACTOR FOR THERMOSTAT CONNECTION. MOUNT BOTTOM OF HEATER 7'-0" QMARK MUH0541 CL o co ABOVE FLOOR. * * PANEL SCHEDULE G SPACE - - 13 14 - - SPACE SPACE - - 15 16 - - SPACE SPACE - - 17 18 - - SPACE CONNECTION LOAD: DEMAND: LIGHTING 8c RECEPTACLE LOAD DEMAND LOAD: 4.1 KVA 11.2 AMPS 4.1 KVA 11.2 AMPS TYPE DESCRIPTION MANUFACTURER MANUFACTURER CATALOG N0. LAMP LAMP REMARKS * LED LIGHT FIXTURE, 120 VAC, 4'-4" LONG, 45 WATT, 5000K Al COLOR TEMPERATURE, 60,000 HOUR LED, HIGH EFFICIENCY INTEGRATED LITHONIA FEM L48 6000LM IMAFL 50K 1 z DRIVER, HIGH -IMPACT ACRYLIC LENS, MOLDED FIBERGLASS LED HOUSING, CEILING MOUNTED, U.L. LISTED FOR WET LOCATIONS. LED OUTDOOR AREA LIGHT - (1)-27W 10C LED. 700mA, 5000K DSXW1 LED 10C 700 50K T3M 120 INTEGRATED A2 COLOR TEMPERATURE, 120VAC, MOUNT BOTTOM OF FIXTURE 1'-0" LITHONIA DDBXD 1 LED ABOVE DOOR, U.L. LISTED FOR WET LOCATIONS. DUAL HEAD EMERGENCY LIGHT - (2)-1.8W LED LAMPS, Z DUAL -VOLTAGE INPUT 120VAC/277VAC, 3 3/4" H, 14 5/8" W, 0 A3 THERMOPLASTIC HOUSING, INTEGRATED RECHARGEABLE BATTERY, LITHONIA EU2 LED M12 2 1.5 WATT DC � MOUNT BOTTOM OF FIXTURE 1'-0" ABOVE DOOR, U.L. LISTED FOR DAMP LOCATIONS. W LED POLE MOUNTED LIGHT - (1)-140W 80C LED. 530mA, 5000K 0 COLOR TEMPERATURE 120VAC, WITH FUSE PROTECTION, PROVIDE M co m PROVIDE WITH FIXTURE WITH BRACKETRY TO MOUNT TO VENTILATION POLE. LIGHT - DSX2 LED P1 50K TFTM 120 (V O d A4 LITHONIA N/A 140 WATT PHOTOCELL PROVIDE FIXTURE WITH INTEGRATED PHOTOCELL CONTROL. U.L. RPA SF DDBXD CONTROLLER LISTED FOR WET LOCATIONS. SEE DWG N0. E018 FOR INSTALLATION DETAILS. A5 BOLLARD LIGHT - (1) 12.6W LED. 1023 LUMEN, 4000K COLOR BEGA LIGHT - 84 674 1 12.6 WATT co co TEMPERATURE, 120VAC. ANCHORAGE - 79 825 (V WALL LED - 120VAC, 2,000-9,200 LUMENS ADJUSTABLE ADJUSTABLE OUTPUT A6 OUTPUT, 5000K COLOR TEMPERATURE. LITHONIA TWH LED ALO 50K T3M 120 DDBXD 1 44 WATT NOT TO EXCEED STEP 4 LED LIGHT FIXTURE - 120 VAC, 4' LONG, 47 WATT, 5000 W A7 LUMENS, 5000K COLOR TEMPERATURE, CEILING MOUNTED. HOLOPHANE HXLP L48 2 5000LM 120 50K 2 47 WATT EXPLOSION PROOF, RATED FOR CLASS 1, DIVISION 1 LOCATIONS. SCALE: SHOWN NEMA TYPE 12 ENCLOSURE, 3'-0" Q 20" DEEP. of WAS11 S 57189 NAMEPLATE ° GISTtS MARINA PUMP STATION SIGNED. 0610212023 TELEMETRY PANEL, "RTU-1" OPERATOR INTERFACE SCREEN. INSTALL CENTERLINE OF SCREEN 6-0" ABOVE FINISHED FLOOR. C/) w w O OPERATOR IN TROUBLE U �' + D PUSHBUTTON. INSTALL TOP O OF DEVICE 4'-0" ABOVE ~ FINISHED FLOOR. � Z INTRUSION DISABLE PAD -LOCKABLE HANDLE OOSWITCH. DO NOT LABEL. O J P-1 W cn z ALARM LIGHT 6'_011113 00 ALARM RESET �--� PUSHBUTTON EMERGENCY U Z WET WET LEVEL STORAGE LEVEL TRANSMITTER TRANSMITTER SELECTOR SWITCH SELECTOR SWITCH (PT LEVEL/RADAR) (PT LEVEL/RADAR) WET WET LOW FLOAT BYPASS SWITCH EMERGENCY STORAGE LOWS FLOAT BYPASS SWITCH �y°o WET WELL BACKUP PUMP SELECTION SWITCH cn (P1-P2/P2-P3/P3-P1) 0 0 Y W cc 0 0 LL o oco m COMBINATION ETHERNET z m PORT/RECEPTACLE c� 0 U w w (n o z cn Oo_ _ a (/� O w z W W W o WARNING LABEL U o 0 WARNING Q 120 VAC cli c� co KEEP OUT 0 Lu Of 0 o- ZO L.L (V N o w a W cn =D > U U) LL W Lu Q ~ ¢ O � ti co co a N N N M O (V Q 303 PROPOSED CONCRETE m co o 0 5703 EQUIPMENT PAD Y W z W �< TELEMETRY PANEL EXTERIOR LAYOUT W cr SCALE: SHOWN NOT TO SCALE Oil 1 2 DRAWING IS FULL SCALE WHEN BAR MEASURES 2" DWG NO.: SHEET NO.: E024 116 123 120P 120 VAC 1 PH 60HZ FROM PANEL "L" 1CB / GND O 20A f L1 L LINE SURGE N L2 L PROTECTOR N 2CB L3 3CB L4 DOOR SWITCH D C 120N Do- N1 N2 AC POWER FAIL PF CR N3 —0 LIGHTS N4 4CB COMBINATION ETHERNET L5 PORT/RECEPTACLE. GRACE PORT P-R2-K4RF0. LOCATED ON RTU. 5CB L6 SPARE 6CB L7 POWER SUPPLY 24VDC 7CB DPF + DC IN 24 VDC DC IN - UPS BATTERY BATT MODULE 24P + DC OUT DC OUT - 8CB 24P1 + DC IN POWER SUPPLY DC IN - + DC OUT 24VDC TO 24VDC DC OUT - 9CB PLC POWER SUPPLY 1 Al 10CB PLC POWER SUPPLY 2 1769-PB4 I'ICB ETHERNET SWITCH 12CB OPERATORINTERFACE 13CB D 24P2 + DC IN POWER SUPPLY DC IN - + DC OUT 24VDC TO 12VDC DC OUT - 14CB RADIO 15CB D 24P3 DISCRETE INPUTS 16CB � 24P4 D DISCRETE OUTPUTS 17CB � 24P5 D ANALOG INPUTS 18CB 24P6 FLOW METER TRANSMITTER D (INSTALL IN RTU) 19CB D 24P7 AIR QUALITY MONITOR LIGHTS 20CB 24P8 21CB 24P9 22CB 24P10 23CB ALARM HORNS/LIGHTS GAS MONITORS AIRFLOW SWITCHES 24P11 WET WELL BACKUP FLOAT CONTROL (IN RTU) 24CB � 24P12 ) EMERGENCY STORAGE BACKUP FLOAT CONTROL (IN RTU) 25CB D 24P13 � SPARE 0-106. 24P14 SPARE POWER LAYOUT NOT TO SCALE N5 N6 N7 24N FIELD CONNECTIONS COMMUNICATIONS LAYOUT NOT TO SCALE RA SIGNED. 0610212023 C/) w 0 w Q Q V V� Z D 0 _ Z Q 0 � � 0 V Q Q Q W VZ O a a F- o� U) of Y AR u- JA m 0 JA c� 0 U w w c1l) o Z a_ 0 0 (n o w z W W W o z w o Q 0 Q co co coc\j of oN o w 0 a u- M N M N 0 0 W w cn c/) W 0 0 O co co c- N N ON C9 CO 0 cf) CD CD m � Y W W Z W O WLu 'I m z 0 a cr- U co W 0 o�z SCALE: SHOWN oil r 211 DRAWING IS FULL SCALE WHEN BAR MEASURES 2" DWG NO.: SHEET NO.: E025 117 123