2-Melcher Pump Station Rehab-Bid Set Drawings-with Generator-signedORCHARD �iiiiiiiiiiiiIIIIIIIIIIIIII-IIIII0-- MELCHER STREET N RENOVATION SIDNEY AVENUE AT MELCHER STREET PORT ORCHARD, WASHINGTON 98366 r RVJLV I LV V/'11 IVIV NORTH BID SET 16-FEB-2024 VICINITY MAP r _ r� j� I w wJW z ,.1 r _ MELCHER STREET . � �„�, y '- F � „ �j _ i wry. �+ 'f. �"'•5 sPROJECT LOCATION -' 4 it NOT TO SCALE DESIGN TEAM: i ® ART ANDERSON 830 PACIFIC AVE, BREMERTON, WA 98337 (360)479-5600 IN ASSOCIATION WITH: Technical Systems Inc. Consor Engineers SITE ADDRESS: 1201 SIDNEY AVENUE PORT ORCHARD, WA NORTH SHEET INDEX SHEET # SHEET DESCRIPTION G-001 SHEET INDEX AND VICINITY MAP G-002 NOTES C-101 PUMP STATION SITE PLAN D-101 DEMOLITION PLAN AND ELEVATIONS S-201 STRUCTURAL PLAN S-501 STRUCTURAL DETAILS M-001 MECHANICAL GENERAL NOTES, ABBREVIATIONS, AND SYMBOL LEGEND M-201 MECHANICAL PLAN M-501 MECHANICAL DETAILS E-001 ELECTRICAL GENERAL NOTES, ABBREVIATIONS AND SYMBOL LEGEND E-201 ELECTRICAL PLAN E-202 LIGHTING PLAN E-501 ELECTRICAL ONE LINE DIAGRAM E-601 ELECTRICAL PANEL SCHEDULE DETAIL PC-001 TSI PUMP CONTROL DWG, CONTROL PANEL BOM PC-002 TSI PUMP CONTROL DWG, CONTROL PANEL BOM PC-003 TSI PUMP CONTROL DWG RTU 10-10.01, PANEL LAYOUT PC-004 TSI PUMP CONTROL DWG RTU10-10.04, BACKPAN LAYOUT PC-005 TSI PUMP CONTROL DWG RTU10-10.06, PLC RACK LAYOUT PC-006 TSI PUMP CONTROL DWG RTU10-10.09, CONTROLS DETAIL PC-007 TSI PUMP CONTROL DWG RTU10-10.10 NAMEPLATE LAYOUT PC-008 TSI PUMP CONTROL DWG RTU-10-20.01, OVERVIEW NETWORK DIA PC-009 TSI PUMP CONTROL DWG RTU-10-20.30, NETWORK SWITCH PC-010 TSI PUMP CONTROL DWG RTU-10-30.01, 480V POWER DIST DIA PC —Oil TSI PUMP CONTROL DWG RTU-10-30.10, 120V POWER DIST DIA PC-012 TSI PUMP CONTROL DWG RTU-10-30.20, 480V P24VDC UPS PWR DIST DIA PC-013 TSI PUMP CONTROL DWG RTU-10-40.101 A, RACK 1, SLOT 01—WIRING DIA PC-014 TSI PUMP CONTROL DWG RTU-10-40.101 B, RACK 1, SLOT 01—WIRING DIA PC-015 TSI PUMP CONTROL DWG RTU-10-40.102A, RACK 1, SLOT 02—WIRING DIA PC-016 TSI PUMP CONTROL DWG RTU-10-40.102B, RACK 1, SLOT 02—WIRING DIA PC-017 TSI PUMP CONTROL DWG RTU— 10-40.1 03A, RACK 1, SLOT 03—WIRING DIA PC-018 TSI PUMP CONTROL DWG RTU-10-40.103B, RACK 1, SLOT 03—WIRING DIA PC-019 TSI PUMP CONTROL DWG RTU-10-40.104A, RACK 1, SLOT 04—WIRING DIA PC-020 TSI PUMP CONTROL DWG RTU-10-40.104B, RACK 1, SLOT 04—WIRING DIA PC-021 TSI PUMP CONTROL DWG RTU— 10-40.1 05A, RACK 1, SLOT 05—WIRING DIA PC-022 TSI PUMP CONTROL DWG RTU-10-40.105B, RACK 1, SLOT 05—WIRING DIA PC-023 TSI PUMP CONTROL DWG RTU-10-50.01, VPD CONTROL WIRING DIA PC-024 TSI PUMP CONTROL DWG RTU-10-50.02, VPD CONTROL WIRING DIA PC-025 TSI PUMP CONTROL DWG RTU-10-99.01, ANTENNA INSTL DETAIL DIA SHEET IS 22x34 ANSI D IF PRINTING 1 1 x 17 USE 50% SCALE FACTOR r- (y) M 00 >Q Z 0 H W 2 W of Co W Q O U co LL L? Qv ao 0o M W 110o Q � �0 25394 ww I STEREO SS10NAL z O w � 0 w � z a, u' M � z M O O = CF) < w = C/) Q a Q � � � w o F--- za w LU w � a � O w w � p O = U C/) � J W DRAWN: CWB DESIGNED: SMH CHECKED: RBG ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITLE SHEET INDEX AND VICINITY MAP CHT NO 1 ;;I 39 G-OO>I GENERAL NOTES 1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH PROJECT SPECIFICATIONS, CITY STANDARDS AND THE ENGINEERING DESIGN AND CONSTRUCTION STANDARDS. NOTHING IN THE DRAWINGS OR SPECIFICATIONS SHALL BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO APPLICABLE CODES. INSTALL MATERIALS AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2. ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH PROJECT SPECIFICATIONS, CITY STANDARDS AND THE ENGINEERING DESIGN AND CONSTRUCTION STANDARDS. NOTHING IN THE DRAWINGS OR SPECIFICATIONS SHALL BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO APPLICABLE CODES. INSTALL MATERIALS AND EQUIPMENT ABBREVIATIONS SYMBOL LEGEND SYMBOL LEGEND, CONT. Q W Z Q M co z o m Q o �� -L? Q o o c M A OR AMPS AMPERES AFF ABOVE FINISHED FLOOR AIC AMPERE INTERRUPTING CAPACITY ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BKR BREAKER BLDG BUILDING BTFLY BUTTERFLY C CONDUIT CL CENTERLINE SYMBOL DESCRIPTION SYMBOL DESCRIPTION EXISTING TO REMAIN LINETYPE ELECTRICAL CONDUIT ROUTED IN WALL OR OVERHEAD - (2) #12 CONDUCTORS AND (1) #12 GROUND UNLESS OTHERWISE NOTED. ' ' ' ' ' EXISTING TO BE REMOVED (DASH SCALE VARIES) NEW ELECTRICAL CABLING PROVIDE (2) #12 AND A #12 GROUND UNLESS OTHERWISE NOTED ELECTRICAL CONDUIT ROUTED UNDERGROUND - (2) #12 CONDUCTORS AND (1) #12 GROUND UNLESS OTHERWISE NOTED. EXISTING ELECTRICAL CONDUIT ROUTED IN WALL OR OVERHEAD - (2) #12 CONDUCTORS AND (1) #12 GROUND UNLESS OTHERWISE NOTED. PREWIRED SYSTEM FURNITURE CABLING (BY OTHERS) PROVIDE PATHWAY AND CABLING TO SUPPORT CONNECTION PER MANUFACTURER SPECIFICATIONS EXISTING ELECTRICAL CONDUIT ROUTED UNDERGROUND - (2) #12 CONDUCTORS AND (1) #12 GROUND UNLESS OTHERWISE NOTED. ELECTRICAL CABLING HOMERUN 3. IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. THE CONTRACTOR SHALL COMPLY WITH ALL SAFETY STANDARDS AND REQUIREMENTS SET FORTH BY OSHA, WISHA AND WASHINGTON STATE DEPARTMENT OF LABOR AND INDUSTRIES. CB CKT CRI CT CIRCUIT BREAKER CIRCUIT COLOR RENDERING INDEX CURRENT TRANSFORMER X-## ��� 'X' REPRESENTS PANEL NAME, '##' REPRESENTS CIRCUIT NUMBER, LONG TICK REPRESENTS NEUTRAL, SHORT TICK REPRESENTS HOT CONDUCTOR. ELECTRICAL CONDUIT OR CABLE TO BE REMOVED. � NON -FUSED DISCONNECT SWITCH. REFER TO ASSOCIATED FLAG NOTES FOR VOLTAGE RATING, AMPERAGE RATING, AND ADDITIONAL INFORMATION. O CEILING MOUNTED JUNCTION BOX a FUSED DISCONNECT. REFER TO ASSOCIATE FLAG NOTES FOR VOLTAGE/AMPERAGE RATING AND ADDITIONAL INFORMATION FUSED DISCONNECT SWITCH. REFER TO ASSOCIATED FLAG NOTES FOR VOLTAGE RATING, FUSE AMPERAGE RATING, AND ADDITIONAL INFORMATION. PROVIDE (2) SPARE FUSES FOR FUTURE USE. 4. 5. ALL APPROVALS AND PERMITS REQUIRED BY THE CITY AND WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES SHALL BE OBTAINED BY THE CONTRACTOR PRIOR TO STARTING CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING WORK. IF EXISTING CONDITIONS DO NOT CLOSELY MATCH CONDTIONS SHOWN ON DRAWINGS, OR IF EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE AUTHORITY HAVING JURISDICTION PRIOR TO COMMENCING THE WORK. (E) OR DI DIAL DIA DB DISC EXST ELEC EMER EMT DUCTILE IRON DIAGRAM DIAMETER DISTRIBUTION BOARD DISCONNECT EXISTING ELECTRICAL EMERGENCY ELECTRICAL METALLIC TUBING .� � •wAHO� `V�CF °F '�I��& �� �° cp NON -FUSED DISCONNECT. REFER TO ASSOCIATE FLAG NOTES FOR VOLTAGE AMPERAGE RATING AND ADDITIONAL INFORMATION / ATS AUTOMATIC TRANSFER SWITCH. REFER TO ASSOCIATED FLAG NOTES FOR ADDITIONAL INFORMATION. ® SPECIALTY RECEPTACLE REFER TO ASSOCIATED FLAG NOTES FOR VOLTAGE/ AMPERAGE RATING AND ADDITIONAL INFORMATION. DRY -TYPE TRANSFORMER. REFER TO ASSOCIATED NOTES FOR PRIMARY AND SECONDARY VOLTAGES, KVA RATING, PHASE COUNT AND ADDITIONAL INFORMATION. DUPLEX RECEPTACLE PROVIDE (2) #12 & A #12 GROUND AND MOUNT AT 18"AFF UON E°°® ELECTRICAL EQUIPMENT (SIZE VARIES). REFER TO ASSOCIATED FLAG NOTES AND SINGLE LINE DIAGRAM FOR ADDITIONAL INFORMATION. 6. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES AND PUMP STATION FEATURES TO BE RETAINED. HANDLE, STORE, AND PROTECT EQUIPMENT, MATERIALS, AND STRUCTURE TO PREVENT DAMAGE, CORROSION, OR CONTAMINATION. ENCL EW F () FLA ENCLOSURE EACH WAY FUTURE FULL LOAD AMPS �0 25394 �ECISTE ss IDNAL ww� VFD VARIABLE FREQUENCY DRIVE PROVIDE (2) #12 & A #GFCI DUPLEX RECEPTACLE 12 GROUND AND MOUNT AT 18"AFF UON *Mic DEDICATED GFCI DUPLEX RECEPTACLE FOR MICROWAVE PROVIDE (2) #12 WITH A #12 GROUND AND MOUNT AT 18" AFF 7. PREPARE SURFACES TO RECEIVE NEW FINISHES. REPAIR AND PATCH ALL EXISTING SURFACES DAMAGED OR ALTERED BY NEW WORK. ALL NEW FLG FLANGED GEN GENERATOR z AND PATCHED SURFACES SHALL BE SMOOTH, CONTINUOUS, FREE OF GFCI GROUND FAULT CIRCUIT INTERRUPTER UON 0 DEDICATED GFCI DUPLEX RECEPTACLE FOR REFRIGERATOR IMPERFECTIONS, AND IN PROPER CONDITION TO RECEIVE THE FINISH. GND GROUND I- 8. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR FURNISHING, INSTALLING AND MAINTAINING WARNING SIGNS AND DEVICES NECESSARY TO HP IEC HORSEPOWER INTERNATIONAL ELECTRICAL CODE (jREF PROVIDE (2) #12 WITH A #12 GROUND AND MOUNT AT 18" AFF UON Q O w W CM DOUBLE DUPLEX RECEPTACLE PROVIDE (2) #12 WITH A #12 GROUND AND MOUNT AT 18" AFF SAFEGUARD THE PUBLIC AND KEEP THE SITE SECURE DURING WORKING AND NON -WORKING HOURS. WATER UTILITY NOTES 1. UNLESS OTHERWISE INDICATED IN THE APPROVED CONSTRUCTION DOCUMENTS ALL WATER MAINS SHALL BE DUCTILE IRON, STANDARD CLASS 52 AND INSTALLED PER AWWA C600. 2. GATE VALVES SHALL BE RESILIENT WEDGE, NON -RISING STEM WITH 0-RING SEALS. VALVE ENDS SHALL BE MECHANICAL JOINT OR ANSI FLANGES. VALVES SHALL CONFORM TO AWWA 509 OR C515. ACCEPTABLE VALVE MANUFACTURERS ARE MUELLER, M & H, KENNEDY OR CLOW. 3. EXISTING VALVES SHALL BE OPERATED BY AUTHORIZED CITY PERSONNEL ONLY. 4. WATER MAINS AFFECTED BY THIS PROJECT SHALL BE CHLORINATED AND TESTED IN ACCORDANCE WITH SPECIFICATION SECTION XX XX XX. 5. THE CITY SHALL BE GIVEN 72 HOURS NOTICE PRIOR TO A SCHEDULE WATER SYSTEM SHUTDOWN. 6. WATER MAIN JOINTS AND FITTINGS SHALL BE RESTRAINED USING FLANGE JOINTS UNLESS OTHERWISE INDICATED. JB OR PH JBOX KCMIL KVA LC MAX MCC MECH MIN MTS (N) NEC NEMA NIC NTS OR PNL R RCPT RDC RDCR REL RFCA RGS JUNCTION BOX THOUSAND CIRCULAR MIL KILOVOLT AMPERE LOAD CENTER MAXIMUM MOTOR CONTROL CENTER MECHANICAL MINIMUM MANUAL TRANSFER SWITCH NEW NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NOT IN CONTRACT NOT TO SCALE PHASE PANELBOARD RETAIN RECEPTACLE REDUCING REDUCER RELOCATE RESTRAINED FLANGED COUPLING ADAPTER RIGID GALVANIZED STEEL CONDUIT z W z O 0 Q � 0- 0- w W W W = U J W W = U J W [___ Q W =) zLjj > Q >- W z C) C1 co Z � z � Q 3: Q I= = U cr 0 � O bv VIDEO DISPLAY RECEPTACLE PROVIDE (2) #12 WITH A #12 GROUND AND MOUNT AT 84>> AFF UON � DATA RECEPTACLE PROVIDE (2) CATEGORY 6A CABLES UON. SEE CABLE SCHEDULE ON SHEET E501 FOR ADDITIONAL INFORMATION WIRELESS ACCESS POINT LOCATION PROVIDE (1) CATEGORY 6A CABLES WITH 20' SERVICE LOOP ON DEVICE END AND TERMINATE ON MODULAR 8P8C JACK. LIGHTING SWITCH MOUNT AT 42" AFF UON 3 3-WAY LIGHTING SWITCH MOUNT AT 42" AFF UON I--o-� 4' STRIP LIGHT I--�� 4' STRIP LIGHT WITH EMERGENCY LIGHTING PROVISIONS 0 1'x4' LED TROFFER � 1'x4' LED TROFFER WITH EMERGENCY LIGHTING PROVISIONS. RM SCHD ROOM SCHEDULE 2'x4' LED TROFFER SECTION AND DETAIL LOCATION KEY SIM SW SWBD TYP SIMILAR SWITCH SWITCHBOARD TYPICAL DRAWN: DESIGNED: CHECKED: CWB SMH RBG 2'x4' LED TROFFER WITH EMERGENCY LIGHTING PROVISIONS. 0--m POLE MOUNTED LUMINAIRE - 1 HEAD ISSUE DATE 2/16/2024 SECTION NUMBER DESIGNATION 1 D101 UPS V VA XFMR UNINTERRUPTIBLE POWER SUPPLY VOLTS VOLTS AMPERE TRANSFORMER POLE MOUNTED LUMINAIRE - 2 HEADS (90°) �m POLE MOUNTED LUMINAIRE - 2 HEADS (180°) REVISMG SHEET WHERE SECTION IS SHOWN W WATT POLE MOUNTED LUMINAIRE - 3 HEADS 90° 90° 180° ( / / ) SECTION NUMBER DETAIL NUMBER JOB No DESIGNATION SECTION ::)A ::)g) SCALE: D101 DETAIL SCALE: POLE MOUNTED LUMINAIRE - 4 HEADS FACP0017 SHT TITEE NOTES SHEET WHERE SHEET FROM WHICH SECTION IS TAKEN DETAIL IS TAKEN m EXIT SIGN MATCH EXISTING MANUFACTURER, ELECTRICAL REQUIREMENTS AND BID SET COLOR SCHEME 16-FEB-2024 EMERGENCY LIGHTING SYSTEM BATTERY A DASH IN PLACE OF A SHEET NUMBER INDICATES THAT THE SECTION OR DETAIL IS LOCATED ON THE SAME SHEET. 0 REUSE EXISTING BATTERIES IF SERVICEABLE. PROVIDE ADDITIONAL BATTERIES (MATCH EXISTING) AS REQUIRED. SHEET IS 22x34 ANSI D IF PRINTING 11x17 USE SHT DC G-002 2 OF 39 50% SCALE FACTOR EXST WOOD FENCE TO SIDNEY AVE w Q CD DRIVEWAY BID SET 16—FEB-2024 APPROX LOT LINE GENERATOR ROOM INTAKE LOUVER M M 00 >Q z 0 ry W 7- W 0o w ao U c0 rn Qv ao 00 M W M - I10 OF WAS Q � 25394 ww� �ECISTER�� SS10NAL Q cD > w (D p w ce) i NEW PUMP STATION ANTENNA SUPPORT z pr co i i SHEETS 201 i w z z O w U z EXST --------- i ----�---------------------- Q J w — UTILITY POLE -- - — — — — — — — — — — — — GENERATOR ROOM 0-Q 3: EXHAUST LOUVER Q D w 0 0- =) w z = w > U a� U) >-O M w zrr LU 00 U C/) n w 75 APPROX LOT LINE -------------- PUMP STATION SITE PLAN SCALE: 1 /2" = V-0" 0 �' 2' 3' 4' 6' SHEET IS 22x34 ANSI D IF PRINTING 11 x 17 USE SCALE: 1 /2" = 1'-0" 50% SCALE FACTOR DRAWN: CWB DESIGNED: SMH CHECKED: RBG SSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITLE PUMP STATION SITE PLAN SHT No 3 OF 39 DEMOLITION PLAN SCALE: 1 /2" = V-0" 0 8" 16" 2' 2'8" 4' 5,4" 8' SCALE: 3/8" = 1'-0" BID SET 16—FEB-2024 0 12' 3' 4' 6' SCALE: 1 /2" = 1'-0" SHEET IS 22x34 ANSI D IF PRINTING 1 1 x 17 USE 50% SCALE FACTOR EXISTING 75HP PUMP EXISTING HOUSEKEEPING PAD FLAG NOTES REMOVE AND SCRAP EXISTING 750 GPM I, -- co co 00 m EXISTING PUMP, 50 HP MOTOR, BASE FRAME AND ASSOCIATED PIPING, CONTROLS AND WIRING. 2 FUEL TANK 2� REMOVE AND SCRAP EXISTING 1000 GPM w EXISTING PUMP, 75 HP MOTOR, BASE FRAME AND O of GENERATOR ASSOCIATED PIPING, CONTROLS AND WIRING. w AND SHROUD REMOVE AND SCRAP EXISTING PIPING, W a o Q ztzzz VALVES, AND FITTINGS. REMOVE AND SCRAP EXISTING UNIT HEATER. I,L Q Z a d o � M REMOVE AND SCRAP CONTROLS ENCLOSURE AND ASSOCIATED CONTROL SYSTEM. / [� REMOVE AND SCRAP 120/240V LIGHTING a 4 AN PANEL. REMOVE AND SCRAP 400A, 480/277V PUMP RM AND GENERATOR RM ELEVATION LOOKING NORTH DISCONNECT. SCALE: 3/8" = V-0" EXISTING - FUEL TANK REMOVE AND SCRAP AUTOMATIC TRANSFER SWITCH (ATS). REMOVE AND SCRAP MOTOR CONTROL CENTER (MCC). 10 BLANKED OFF NATURAL VENTILATION OPENING. REMOVE AND SCRAP EXISTING LOUVERS AND INFILL WITH CMU AND SEAL OPENING. �x - 110 ,3? WAS CQ e °2 tll 25394 ww d'EC I STER�� 1� SSIONAL i 11 DEMOLISH EXISTING CONCRETE THRUST BLOCK BACK TO EXISTING SLAB. Z O 12 EXISTING EQUIPMENT SHIPPING ACCESS IN PUMP STATION ROOF, APPROXIMATELY 3'x4'. W j � _ 13 REMOVE AND SCRAP EXISTING 20OKW , 0 W Cy) 480V, 3 PH GENERATOR AND ALL Z co RM ELEVATION LOOKING WEST SKID, ANDEXHAUSTSYSTEM. PIPING, ASSOCIATEGENERATOR W � Z 4 � PUMP RM ELEVATIONS LOOKING WEST D-101 SCALE: 3/8" = V-0" D14 REMOVE AND SCRAP EXISTING GENERATOR Z m W 0 SCALE: 3/8" = V-0" FUEL TANK. 0 = (D Z 15 REMOVE AND SCRAP EXISTING GENERATOR < � J _ DAY TANK. W EXISTING EXISTING EXISTING U) 120/240V CONTROLS SUSPENDED 16 DEMOLISH EXISTING CONCRETE Q EXISTING 400A, LIGHTING ENCLOSURE HEATER HOUSEKEEPING PAD BACK TO EXISTING Q 480/277V DISCONNECT PANEL SLAB. W Q 17 EXISTING I -BEAMS. RETAIN FOR REUSE FOR NEW GENERATOR SILENCER SUPPORTS. W Z = W EXISTING 18 REMOVE AND SCRAP EXISTING HEAT SHIELD W > U CT CABINET OVER GENERATOR SILENCER. Q EXISTING o C/) >- 0 GENERATOR 19 REMOVE AND SCRAP EXISTING GENERATOR W AND SHROUD x SILENCER. M Z 20 BLANKED OFF NATURAL VENTILATION W = p 0 OPENING. REMOVE AND SCRAP EXISTING C) cn LOUVERS AND REPLACE WITH GALVANIZED J STEEL WEATHER LOUVER AND FRAME WITH W PUMP RM AND GENERATOR RM ELEVATION LOOKING SOUTH INSECT SCREEN. SCALE: 3/8" = V-0" PUMP RM ELEVATION LOOKING EAST ~uomw GENERATOR RM ELEVATION LOOKING EAST 21 REMOVE EXISTING INCANDESCENT LIGHT AND FIXTURE. RETAIN CIRCUIT FOR RE -USE. 22 REUSE EXISTING PIPE SADDLE SUPPORT 23 RETAIN EXISTING McCROMETER FLOW METER REMOTE MOUNT DISPLAY FOR RE -USE. SEE ITEM 910A ON PC-002 AND PC-003. TAKE CARE NOT TO DAMAGE OR OTHERWISE RENDER NON-FUNCTIONAL, THE DISPLAY AND CABLING TO THE EXISTING FLOW METER. 24 REMOVE EXISTING PRESSURE SWITCH. RETAIN CABLING, PIPING AND ANALOG GAGE FOR REUSE. 25 REMOVE EXISTING RECEPTACLE. 26 RETAIN EXISTING RECEPTACLE. DRAWN: CWB DESIGNED: SMH CHECKED: RBG ISSUE DATE 2/16/2024 JOB NO FACP0017 SHT TITLE DEMOLITION PLAN AND ELEVATIONS SHT No 4 CI 39 D-101 SCALE: 3/8" = V-0" SCALE: 3/8" = V-0" STRUCTURAL PAD PLAN SCALE: 1 /2" = V-0" BID SET 16-FEB-2024 CH PUMP ROOM ELEVATION LOOKING WEST SCALE: 3/8" = 1'-0" GENERATOR ROOM ROOF PUMP ROOM ROOF PUMP ROOM ELEVATION LOOKING NORTH SCALE: 3/8" = V-0" ANTENNA CLAMP DETAIL SCALE: 3" = 1'-0" PUMP ROOM ELEVATION LOOKING EAST SCALE: 3/8" = V-0" 5° ANGLE CONNECTOR 2125 UNISTRUT CHANNEL BRACE 0 8" 16" 2, 2'8" 4 514„ 8' SCALE: 3/8" = 1'-0" 45° ANGL ANCHOR TO ROOF ROOF ANCHOR DETAIL SCALE: 3" = 1'-0" 0 1' 2' 3' 4' 6' SCALE: 1 /2" = 1'-0" SHEET NOTES co co 1. NOT USED Q z O FLAG NOTES w oLu m (1) w 9"+/- THICK CONCRETE PUMP LJ.I U c0 m EQUIPMENT PAD. 52"x12'-0". Z a o DETAIL 6, SHT S-501 a Q M � co / PUMP STATION ANTENNA SUPPORT ON ROOF OF PUMP STATION. SEE DETAIL 4/S-201. THRUST RESTRAINT FOUNDATION PER DETAIL 1, SHT S-501 EXISTING 12" THICK CONCRETE SLAB INDEPENDENT FROM FLOOR SLAB. APPROX. 40"x8'-4" (REF). / THRUST RESTRAINT FOUNDATION HOUSEKEEPING PAD PER DETAIL 4, SHT S-501. 24"x24"x4". ANCHOR UNISTRUT TO CMU WITH 3/8" SIMPSON TITEN HD MASONRY ANCHORS, 1-3/4" EMBEDMENT. ANCHOR UNISTRUT TO PUMP ROOM ROOF WITH 3/8" SIMPSON TITEN HD CONCRETE ANCHORS, 3-1/4" EMBEDMENT. ANCHOR TO CMU IISTRUT JANNEL BRACE 2" 4" 8" 12" SHEET IS 22x34 ANSI D IF PRINTING 1 1 x17 USE SCALE: 3" = 1'-0" 50% SCALE FACTOR M . 110 Uj P Sean Hoy —:AO 09 A 6C00000 F5 2024 02 394 wW ONAL z O Q O z W z 0 H Q H ZD w w H cn m w U J W 75 w � w cy) H � � Z a� O w � 2 ('3 U Z J = W c/) � Q Q W � W = U Q ❑C } O w � z ❑y- 00 DRAWN: CWB DESIGNED: SMH CHECKED: RBG ISSUE DATE 2/16/2024 JOB NO FACP0017 SHT TITLE STRUCTURAL PLAN SHT No 5 OF 39 S-201 SHEET NOTES 1 SEENOTE SF- i R7%8" BOLT CIRCLE (APPROX.) SEE NOTE + 1" GROUT PAD 10 > = 3 4 3 o 1 24"x24"x4" HOUSEKEEPING PAD QD SEE DETAIL 4/S-501 a EXST SLAB .0 a NOTE: MATCH DRILL HOLES TO PIPE zl THREADED EPDXY ANCHOR a FITTING FLANGE BOLT HOLES. EMBED MIN 2" INTO EXST SLAB. ANCHOR WITH HILTI HY-200 8" (REF) EPDXY OR EQUAL. 91 THRUST RESTRAINT FDN ELEVATION SCALE: 1-1/2" = V-0" 2'-0" EMBED BARS 4" IN EXST SLAB. ANCHOR WITH HILTI HY-200 EPDXY OR EQUAL. al I I ° I a a HOUSEKEEPING PAD DETAIL ELEVATION SCALE: 1-1/2" = V-0" 1. ALL FABRICATION, WELDING, AND INSPECTION SHALL BE TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE. 2. ENSURE THAT 7/8"-9 CONCRETE ANCHORS ACHIEVE 6" EMBEDMENT. FLAG NOTES BASE PLATE, 16%16", 3/4" THK. RESTRAINT PLATE, CUT BOTTOM TO SUIT BASE PLATE FITUP. 20"x16", 1" THK. CHOCK BRACKET, 10-1 /4"x9", 3/4" THK. CHOCK BRACKET, 6-1 /2"x5-1 /2", 3/4" THK. M M 00 z 0 w 2 w w m w ao 20 L? U � ao 0(0 M W z 0 cn w W I.f. z Q Q 11111110 NOW M - I10 01F WAS �0 25394 ww� �ECISTER�� SSI�NAL z 1,-4„ 2,-0„ 0 1" (TYP) 3 > %2W co S-501 a 4 EA #4 AT 6" OC 0 W� 1%2" (TYP) a z � � a a W A v � z a - 3 EA #4 � 1" z GROUT PAD L O SPACE TO AVOID CONFLICT W � WITH THRUST RESTRAINT 0 _ CDa FDN ANCHOR BOLTS. U z _ as i N _i 01 " HOLE (TYP) N z� Q a a J= W � U) z a ° 24 x24 x4 HOUSEKEEPING PAD a 0- Q a SEE DETAIL 5/S-501 a a Q 3: a W 0 0- =) im z 23/ " TYP LU = 4 (TYP) Lu > U a� 5 HOUSEKEEPING PAD DETAIL PLAN 0 2 THRUST RESTRAINT FDN PLAN S-501 SCALE: 1-1/2" = V-0" 1jj - SCALE: 1-1/2" = V-0" w z _ 00 U C/) n 10%4 W (TYPI G %" THREADED EPDXY ANCHOR (TYP) EXST SLAB 6%2" (TYP) 1" GROUT PAD 24"x24"x4" HOUSEKEEPING PAD THRUST RESTRAINT FDN SECTION SCALE: 1-1/2" = V-0" #5 AT 6" EAC BEND EVERY OTHE DOWN AND EM EXST SLAB 4". A WITH HILTI HY-200 c z a V a a PUMP EQUIPMENT PAD DETAIL SECTION SCALE: 1-1/2" = V-0" BID SET 16—FEB-2024 D) a'AM: CWB DESICKED: SMH CHECKED: RBG ISSUE DATE 2/16/2024 REVISIONS JOB No FACP0017 SHT TITHE STRUCTURAL DETAILS 0 2" 4" 6" 12 2' SHEET IS 22x34 ANSI D IF PRINTING 11 x 17 USE SCALE: 1 1 /2" = 1'-0" 50% SCALE FACTOR SHT No 6 OF 39 S-501 ti M M 00 >0') Z O w Z w Oco m � w WCD W � 0 co Zo� Q Q co co00 0 El of WAS � f �a o� tll �� 25394 ww `�� PE-1 ST ONAL Z > W C� O W o0 z � a, W °C U)z or-O z W O = U z J = � W � Q Q _ W C) � � w z = W > U Q cr ~ >- O W or-z W p O U U W 75 DRAWN: CWB DESIGNED: SMH CHECKED: RBG ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITLE MECHANICAL GENERAL NOTES, ABBREVIATIONS, AND SYMBOL LEGEND BID SET SHT No 7 of 39 16 FEB-2024 SHEET IS 22x34 ANSI D IF PRINTING 1 1 x 17 USE 50% SCALE FACTOR M-001 VALVE SCHEDULE MARK TYPE SIZE (IN) PATTERN SPEC END DETAIL MATL PRESS CL VOLTS NOTES MANUFACTURER & MODEL NUMBER BODY TRIM V-1 BOOSTER PUMP CONTROL 6 GLOBE ASTM A536 FLG DI CI 300 24 [1] CLA-VAL-60-11 V-2 BOOSTER PUMP CONTROL 6 GLOBE ASTM A536 FLG DI CI 300 24 [1] CLA-VAL-60-11 V-3 INLET ISOLATION 8 BUTTERFLY FLG V-4 INLET ISOLATION 8 BUTTERFLY FLG V-5 OUTLET ISOLATION 6 GATE FLG V-6 OUTLET ISOLATION 6 GATE FLG NOTES: [1] WITH FLOW CLEAN STRAINER, ISOLATION VALVE, PRESSURE GAUGE, AND "Y" STRAINER OPTIONS. PUMP SCHEDULE MARK CAPACITY (GPM) TDH (FT) SIZE BHP MOTOR TYPE NOTES MANUFACTURER &MODEL NUMBER EQUIP WEIGHT SUCTION DISCHARGE HP VOLT PH RPM P-1 950 260 5" 4" 81 100 480 3 3600 BASE MOUNT, SPLIT CASE [1], [2] FAIRBANKS-NUIJHUIS, 4" 1822B PS 2, OAE xxxx P-2 950 260 5" 4" 81 100 480 3 3600 BASE MOUNT, SPLIT CASE [1], [2] FAIRBANKS-NUIJHUIS, 4" 1822B PS 2, OAE xxxx UNIT HEATER SCHEDULE MARK TYPE LOCATION CAPACITY BTUH ELECTRICAL NOTES MANUFACTURER &MODEL kW VOLT PH UH-1 CEILING MOUNT PUMP ROOM 17,065 5 240 1 [1] DAYTON 3UG73, OAE UH-2 CEILING MOUNT GEN ROOM 17,065 5 240 1 [1] DAYTON 3UG73, OAE NOTES: [1] WITH CEILING MOUNTING BRACKET AND INTEGRAL THERMOSTAT MECHANICAL AND PIPING PLAN SCALE: 1 /2" = V-0" BID SET 16-FEB-2024 0 1' 2' 3' 4' 6' SCALE: 1 /2" = 1'-0" 0 8" 16" 2 2'8" 4 514„ 8' SCALE: 3/8" = 1'-0" DI PIPE PUMP ROOM AND GENERATOR ROOM ELEVATION LOOKING NORTH SCALE: 3/8" = V-0" KEY NOTES O10"x 10"x8" DI TEE, FLG <�> 10" FLG <�> 10"x8" DI 90° RDC BEND, FLG O8" BTFLY VALVE, FLG O8" DI SPOOL, FLG, FIELD VERIFY LENGTH O8"X5" DI 90° RDC BEND, FLG <�> 6"x4" DI RDCR, FLG M co 00 m >Q z 0 w Z75 w Oof m V) w Qo W �2 co L? I,L Z d o Q o m M 0 ❑ a u U U �& • HO OF wasyl41 / O ADJUSTABLE PIPE SADDLE SUPPORT N� ANVIL FIG 264 WITH FIG 63 TYPE T CQ 10 02 3 PIPE STANCHION, OAE 4 <�> 6" DI 45° BEND, FLG � 0 `��SSI v � 2IST wW CISTER�����'� V-5LFL — 1 V ANAL P-1 V-3 5 10 6" RFCA o z 11 10"x6" DI RDCR, FLG O 8 7 6 12 9 8 7 6 12 6" DI 22.5° BEND, FLG O > W C0 rr CO PUMP ROOM ELEVATIONS LOOKING WEST PUMP ROOM ELEVATION LOOKING WEST 13 10"x1o"x6" DI TEE, FLG 0 z w M 4 SCALE: 3/8" = V-0" -201 SCALE: 3/8" = 1'-0" Ir �z 15 O 14 UNIT HEATER, 5kW, 240 VOLT z W O = U z 15 GENERATOR SILENCER, CRITICAL CLASS, < W = 12 11 14 SIDE INLET END OUTLET, 5" ASA Q FLANGED END, CUMMINS 0155-2342 —03 OAE, PROVIDE 4" NPT x 5" 0— \\-F Z FLANGE FLEX BETWEEN GENSET AND Q SILENCER. PROVIDE 5" DIA (NOMINAL) LJJ< 0 — WELDED STEEL PIPE, FLANGE, AND O_ = FITTING ON OUTLET END OF SILENCER. z Q IL ROUTE EXHAUST THROUGH EXISTING W W = V-6 V-5 WALL PENETRATION. PROVIDE SUPPORT W > U FROM EXISTING I —BEAMS. Q cr 1/2" SCH 40 PVC PUMP CASING/ O U) W CONTROL VALVE DRAINM � z 17 1 " SCH 40 PVC PUMP CASING/ W o O_ CONTROL VALVE DRAIN. ROUTE TO C) W 0— EXISTING FLOOR DRAIN. J PUMP ROOM AND GENERATOR ROOM ELEVATION LOOKING SOUTH <0> NEW STATIONARY LOUVER, 6" DEEP. W 5 GALVANIZED STEEL, MILL FINISH, RUSKIN -201 SCALE: 3/8" = 1'-0" °' L681 1 S OAE. PROVIDE 1 /2 GALVANIZED 15 WIRE MESH BIRD SCREEN. DRAWN: CWB <3>REUSE EXISTING PIPE SADDLE SUPPORT. DESIGNED: SMH CHECKED: RBG 20 6" FLANGE �ssuE DATE 2/16/2024 21 PRESSURE SWITCH, BOURDON TUBE REVISIONS TYPE, SPST, NORMALLY OPEN, 10A @ 120VDC/5A @240VDC, 10-200 PSIG RANGE, 8 PSI DEADBAND, DWYER/ MERCOID DA-31-2-8 OR APPROVED EQUAL. I JOB NO GENERATOR ROOM ELEVATION LOOKING EAST SHEET IS 22x34 ANSI D IF PRINTING 1 1 x 17 USE 50% SCALE FACTOR FACP0017 SHT TITLE MECHANICAL PLAN SHT No 8 OF 39 M-201 I SCALE: 3/8" = V-0" r- c) c) 00 rn z O w Z 2 w Oco m cj/)� w LL Q o W U co N� Q rn li Z a v o� Q Q m O a u M 110 NEW PRESSURE SWITCH �,���of WAS,yjN�� CONNECT TO NEW CONTROL PANEL. SEE SHEET PC-014. �0 25394 wW EXST ANALOG PRESSURE GAUGE I s 0NALR 000 z O W co O w CY) Z 00 00 W C/) Z °C or O z w O _ � EXST 10" PIPE (,� Z J = W cf) Q � Q Z) W ------------ W Z = Lu > U 1 PRESSURE GAUGE DETAIL Q 0 SCALE:NONE C/) L � w Z LLJ C) O U C/) J W 75 DRAWN: CWB DESIGNED: SMH CHECKED: RBG ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITLE MECHANICAL DETAILS BIDSET SHT NO 9 of 39 16—FEB-2024 SHEET IS 22x34 ANSI D IF PRINTING 1 1 x17 USE 50% SCALE FACTOR m 501 GENERAL ELECTRICAL NOTES 1. EXCEPT IN DEMOLITION PLANS, AND WHERE OTHERWISE NOTED, ALL NEW CONSTRUCTION IS SHOWN WITH SOLID DARK LINES, AND EXISTING CONSTRUCTION TO REMAIN IS SHOWN WITH "SCREENED" LINES. 2. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. DRAWINGS ARE NOT TO BE SCALED. ALL DIMENSIONS SHOWN RELATING TO EXISTING CONSTRUCTION ARE APPROXIMATE (EXISTING WALLS MAY NOT BE PLUMB AND WALLS MAY NOT BE EXACTLY PARALLEL). THE CONTRACTOR SHALL FIELD VERIFY ALL ACTUAL DIMENSIONS AND CONTACT ENGINEER TO ADDRESS ANY DISCREPANCIES. EXACT LOCATIONS, DISTANCES, ELEVATIONS AND SIMILAR DATA SHALL BE GOVERNED BY ACTUAL FIELD CONDITIONS AND BY THE ENGINEER'S INSTRUCTIONS. 3. IN THE EVENT OF CONFLICT BETWEEN INFORMATION SHOWN ON DRAWINGS AND INFORMATION SHOWN ON THE SPECIFICATIONS, THE MORE STRINGENT SHALL TAKE PRECEDENCE. IF ERRORS IN A DRAWING OR SPECIFICATION OR A VARIATION BETWEEN DIMENSIONS ON DRAWINGS AND MEASUREMENTS AT THE SITE EXIST, THE CONTRACTOR SHALL REQUEST CLARIFICATION PRIOR TO COMMENCEMENT OF WORK. ANY WORK PERFORMED PRIOR TO CLARIFICATION SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 4. ALL DIMENSIONS ARE FACE OF FINISH, FACE OF CONCRETE, TO CENTER LINES OF COLUMNS AND OTHER GRID POINTS AND TO CENTER LINES OF DOORS AND OTHER SCHEDULED OPENINGS U.O.N. 5. VERTICAL DIMENSIONS ARE FROM TOP OF SUBFLOOR (SLAB), EXCEPT WHERE OTHERWISE NOTED TO BE ABOVE FINISH FLOOR (A.F.F.). 6. CEILING HEIGHTS ARE MEASURED TO BOTTOM OF FINISH CEILING OR SUSPENDED CEILING GRID. 7. TYPICAL DETAILS SHALL BE INCORPORATED AT ALL APPROPRIATE LOCATIONS WHETHER REFERENCED OR NOT. CONTACT ENGINEER IF CLARIFICATION IS REQUIRED. 8. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE DIMENSIONS AND ELEVATIONS AT THE SITE. THE CONTRACTOR SHALL COORDINATE THE LAYOUT AND EXACT LOCATIONS OF ALL ELECTRICAL DEVICES WITH THE OWNER IN THE FIELD PRIOR TO PROCEEDING. CONTRACTOR SHALL ALSO VERIFY THAT NO CONFLICT EXISTS WITH ANY MECHANICAL SYSTEMS OR EQUIPMENT AND THAT ALL REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE OF ABOVE EQUIPMENT ARE PROVIDED. THE TOP OF ALL DEVICES SHALL ALIGN WHERE POSSIBLE. 9. PATCH AND REPAIR ADJACENT AREAS OR SURFACES AFFECTED BY DEMOLITION OR BY INSTALLATION OF NEW WORK TO MATCH EXISTING CONDITIONS OR IMPROVEMENTS AS REQUIRED. 10. ALL NEW PENETRATIONS SHALL BE FIRE -STOPPED AS REQUIRED AND SHALL MATCH THE FIRE RATING OF THE ASSEMBLY IT IS PENETRATING. 11. CONTRACTOR SHALL REPAIR OR REPLACE ANY FIREPROOFING THAT IS DAMAGED OR DEGRADED TO MAINTAIN REQUIRED FIRE RATINGS. 12. ELECTRICAL RECEPTACLES SHALL BE STAGGERED TO BALANCE LOADING AND MINIMIZE EMI. 13. ALL ELECTRICAL EQUIPMENT, LIGHTING FIXTURES AND DEVICES SHALL BE UL TESTED AND SHALL HAVE A UL LISTING LABEL. BID SET 16-FEB-2024 ELECTRICAL ABBREVIATIONS A OR AMPS AMPERES AFF ABOVE FINISHED FLOOR AIC AMPERE INTERRUPTING CAPACITY ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BKR BREAKER BLDG BUILDING C CONDUIT CL CENTERLINE CB CIRCUIT BREAKER CKT CIRCUIT CRI COLOR RENDERING INDEX CT CURRENT TRANSFORMER DIAL DIAGRAM DIA DIAMETER DB DISTRIBUTION BOARD DISC DISCONNECT (E) OR EXST EXISTING ECP ENTRY CONTROL POINT ELEC ELECTRICAL EMER EMERGENCY EMT ELECTRICAL METALLIC TUBING ENCL ENCLOSURE (F) FUTURE FLA FULL LOAD AMPS GEN GENERATOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND HP HORSEPOWER IEC INTERNATIONAL ELECTRICAL CODE JB OR JBOX JUNCTION BOX KCMIL THOUSAND CIRCULAR MIL KVA KILOVOLT AMPERE LC LOAD CENTER MAX MAXIMUM MCC MOTOR CONTROL CENTER MECH MECHANICAL MIN MINIMUM MTS MANUAL TRANSFER SWITCH (N) NEW NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NTS NOT TO SCALE PH OR � PHASE PNL PANELBOARD PT POTENTIAL TRANSFORMER R RETAIN RCPT RECEPTACLE REL RELOCATE RGS RIGID GALVANIZED STEEL CONDUIT RM ROOM SCHD SCHEDULE SIM SIMILAR SW SWITCH SWBD SWITCHBOARD TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLTS VA VOLTS AMPERE XFMR TRANSFORMER W WATT ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION EXISTING TO REMAIN LINETYPE EXISTING TO BE REMOVED (DASH SCALE VARIES) NEW ELECTRICAL CABLING PROVIDE (2)#12 AND A #12 GROUND UNLESS OTHERWISE NOTED ELECTRICAL CABLING HOMERUN X-## 'X' REPRESENTS PANEL NAME, '##' REPRESENTS CIRCUIT NUMBER, LONG TICK REPRESENTS NEUTRAL, SHORT TICK REPRESENTS HOT CONDUCTOR. O CEILING MOUNTED JUNCTION BOX FUSED DISCONNECT. REFER TO ASSOCIATE FLAG NOTES FOR VOLTAGE/AMPERAGE RATING AND ADDITIONAL INFORMATION NON -FUSED DISCONNECT. REFER TO ASSOCIATE FLAG NOTES FOR a VOLTAGE/AMPERAGE RATING AND ADDITIONAL INFORMATION SPECIALTY RECEPTACLE ® REFER TO ASSOCIATED FLAG NOTES FOR VOLTAGE/ AMPERAGE RATING AND ADDITIONAL INFORMATION. DUPLEX RECEPTACLE PROVIDE (2)#12 & A #12 GROUND AND MOUNT AT 18"AFF UON GFCI DUPLEX RECEPTACLE PROVIDE (2)#12 & A #12 GROUND AND MOUNT AT 18"AFF UON HALF -SWITCHED DUPLEX RECEPTACLE PROVIDE (2)#12 & A #12 GROUND AND MOUNT AT 18"AFF UON. REFER TO DRAWINGS FOR SWITCHING CONFIGURATION FULL -SWITCHED DUPLEX RECEPTACLE PROVIDE (2)#12 & A #12 GROUND AND MOUNT AT 18"AFF UON. REFER TO DRAWINGS FOR SWITCHING CONFIGURATION ISOLATED GROUND RECEPTACLE PROVIDE (2)#12 & A #12 GROUND AND MOUNT AT 18"AFF UON GFCI DUPLEX RECEPTACLE PROVIDE (2)#12 WITH A #12 GROUND AND MOUNT AT 18" AFF UON DOUBLE DUPLEX RECEPTACLE PROVIDE (2)#12 WITH A #12 GROUND AND MOUNT AT 18" AFF UON LIGHTING SWITCH MOUNT AT 42" AFF UON VFD VARIABLE FREQUENCY DRIVE SHEET IS 22x34 ANSI D IF PRINTING 1 1 x 17 USE 50% SCALE FACTOR z 0 Z w 2 Oof w m V) w Qo W U co F_ 0 Q I,L Z d o Q Q om M W W qCQ 1 4 Ar I 24078 ww �EC1 TER�� 1� "'ZONAL z 0 Q 0 z W z 0 F— Q W W W U) m W U W w coo W M co H cy) C/) Z m O w � = C'3 U z J = W W � Q Q W 0 W = U Q oC >- O w � z o� o O DRAWN: CWB DESIGNED: SMH CHECKED: DPK ISSUE DATE 2/16/20204 REVISIONS JOB NO FACP0017 SHT TITLE ELECTRICAL GENERAL NOTES, ABBREVIATIONS AND SYMBOL LEGEND SHT NO 10 OF 39 E-001 ELECTRICAL PLAN SCALE: 1 /2" = V-0" BID SET 16-FEB-2024 0 12' 3' 4' 6' SCALE: 1 /2" = 1'-0" 0 8" 16" 2 2'8" 4 5'4" 8' SCALE: 3/8" = V-0" PUMP ROOM AND GENERATOR ROOM ELEVATION LOOKING NORTH SCALE: 3/8" = V-0" PUMP ROOM ELEVATIONS LOOKING WEST SCALE: 3/8" = V-0" GENERATOR ROOM ELEVATION LOOKING WEST SCALE: 3/8" = V-0" PUMP ROOM AND GENERATOR ROOM ELEVATION LOOKING SOUTH SCALE: 3/8" = V-0" PUMP ROOM ELEVATION LOOKING EAST SHEET NOTES 1. NOT USED KEY NOTES OCT ENCLOSURE O2 ATS, 400A, 277/480V, 3PH, 4W. CUMMINS MODEL OTEC OAE. O3 VARIABLE FREQUENCY DRIVE (VFD), 10C HP, ALLEN BRADLEY - ROCKWELL AUTOMATION POWERFLEX 753, MODEL 20E-_-A-G-D-125-J-A-0 WITH NEMA/UL TYPE 12 FRAME. PROVIDE WITH 1/0 OPTION KIT 20-750-2263C- 1 R2T AND HUMAN INTERFACE MODULE 20-HIM-A6 WITH COMMUNICATIONS AND ACCESSORIES OPTION 20-750-ENETR, OR APPROVED EQUAL. <�>25 KVA TRANSFORMER OPUMP CONTROL CENTER O6 DIESEL GENERATOR SET, 230 kW STANDBY, 209 kW PRIME, 60 HZ, CUMMINS QSL9-G2, MODEL DSHAD, OPEN FRAME WITH SKID BASE, SPRING ISOLATORS AND 24 HOUR DOUBLE - WALL SUB -BASE TANK, OR APPROVED EQUAL. OMTS, 400A, 277/480V, 3PH, 4W. WIRE UP HANDLE POSITION FOR ONSITE GENERATOR; DOWN HANDLE POSITION FOR GENERATOR CONNECTION BOX. PROVIDE LABELS "ONSITE GENERATOR" AND "PORTABLE GENERATOR" FOR THE HANDLE POSITIONS. 8O PANEL L1, PANEL SCHEDULE ON SHT E-601 O9 GENERATOR CONNECTION BOX, 277/480V, 400A, 3PH, 4W. POWER ASSEMBLIES MODEL GDS-OU 1 C 12 OAE. PROVIDE WITH MECHANICAL LUGS. PROVIDE FOUR CAM -LOCK SINGLE WIRE CONNECTORS, 400A, 600VAC, HUBBELL SERIES 16, COLORS PER CITY OF PORT ORCHARD. 10 RELOCATE EXISTING RECEPTACLE AS REQUIRED. CONNECT TO NEW PANEL. 11 RETAIN EXISTING RECEPTACLE. CONNECT TO NEW PANEL. 12 NEW 15A RECEPTACLE AND CIRCUIT. CONNECT TO NEW PANEL. GENERATOR ROOM ELEVATION LOOKING EAST SHEET IS 22x34 ANSI D IF PRINTING 1 1 x 17 USE 50% SCALE FACTOR M co 00 a z 0 ry w Z 2 w 0co m cl)w Qo W 2 0 Qv Z a o(o M CO 00 0 ❑_ a u W q CQ 10 Ar I 24078 ww �EC1 TER�� 1� SSI�NAL z 0 Q 0 z w Ir z 0 F— C/) W W U) m W U J w w coo W M co H cy) c/) Z m O w � = C'3 U z J = W c/) � Q Q W 0 W = U Q oC >- O w � z o� o O DRAWN: CWB DESIGNED: SMH CHECKED: DPK ISSUE DATE 2/16/2024 Govi64 �[ JOB NO FACP0017 SHT TITLE ELECTRICAL PLAN SHT NO 11 CI 39 E-201 SCALE: 3/8" = V-0" SCALE: 3/8" = V-0" SHEET NOTES M 1. REUSE EXISTING LIGHT SWITCH, J—BOX 00 AND CONDUIT TO THE EXTENT PRACTICABLE. INSTALL NEW #12 0 CONDUCTORS AND #12 GROUND. w 2. RETAIN EXISTING RECEPTACELS AND Z w m 0 RECEPTACLE CIRCUITS. w Qo W U co u- L? KEY NOTES w z a /><as 0 M co CD LOCATION OF EXISTING FIXTURE O NEW LIGHT FIXTURE. SEE LIGHT FIXTURE TO BE REMOVED. (TYP) SPECS ON THIS SHEET. 2 EXISTING LIGHT SWITCH >< O a O3 EXISTING WALL MOUNTED JUNCTION BOX >< P>< �S 1F WA-N, >< 4Z) 0 0 zt � v � �0 24078 wW RECISTER�9 s10NAL L1 z O j W W CM J B 3 � Z � 00 � cr C/) Z z W 0 O = 1 1 U z H W = c/) Q Q W C) =) I= >< W z Q 2 W > U LIGHT FIXTURE SPECS � � � Q > U) W O > M Z ~ W � _ U � J Ol > W 1 DRAWN: CWB DESIGNED: SMH CHECKED: RBG �ssUE TA E 2/16/2024 REVISIONS x x x x x x x LIGHTING PLAN 1 - SCALE: 1 /2" = V-0" JOB NO Ilk FACP0017 SHT TITLE LIGHTING PLAN BID SET 12 39 16-FEB-2024 0 l� 2' 3' 4' s' SHEET IS 22x34 ANSI D IF PRINTING 1 1 x17 USE SCALE: 1 /2" = 1'-0" 50% SCALE FACTOR E-202 LITHONIA LBL4 7200LM 80CR140K NODIM MVOLT BAA, OAE SERIES: LBL4 4" LED WRAP rl— cM cM 00 z 0 H W Z 2 W 0 co //�� 00 cl) W O U(o LL SERVICE W v ENTRANCE Z a 00 (1) 350 MCM ERICKSON 400A CT CABINET W/ Q Q W M FROM UTILITY INTEGRATED DISCONNECT MTS HANDLE POSITION LABLES: MODEL CTMS465NSG, OAE 1. (UP) "ONSITE GENERATOR" M 2. (DN) "PORTABLE GENERATOR" CT (1) 4"C W/ (4) 300 MCM MTS ONSITE GENERATOR & #3 GRND 400A, 277/480, 3PH, 4W CUMMINS QSL9-G2, OAE OPEN GENSET Lo 40OA/3P 1 WITH BASE TANK 600V PUMP ROOM 2 (1) 3" C W/ (4) 500 MCM & #3 GRND ATS (CUMMINS MODEL OTEC, OAE) PORTABLE GENERATOR 400A, 277/48OV, 3PH, 4W CONNECTION BOX NC NO PUMP ROOM P a NSF 1 YC W 4 500 MCM PUMP CONTROL PANEL q �� () / ( & #3 GRND PUMP ROOM - �� 24078 0 �.w SEE TSI DWG RTU 10-30.01 224078 TER �ssloNaL EXISTING 400A I GENERATOR z 200A1 200A1 150A1 0 1 0 SYSTEM PORTABLE GENERATOR BONDING JUMPER > w CD CONNECTION BOX 0 ui Co 7 co (1) 1 "C W/ (2) #4 500 MCM & #10 GRND #3 EQUIPMENT #1/0 GROUNDING (n z SERVICE EQUIPMENT N.I.0 GROUNDING ELECTRODE CONDUCTOR XFMR 1 CONDUCTOR z cr 0 VFD VFD 480-120/240V Lij 25 KVA 0 0 MANUAL 4-POLE _ U z (1) 2"C W/(3) 2/0 TRANSFER SWITCH - Q J = & #6 GRND � LLI (1) 2"C W/(3) 2/0 (1) 1-1 /4"C W/ (3) #2 L 1 GROUNDING Q & #6 GRND & 8 GRND G ELECTRODE100A, 120/24OV, 1 PH, 3W NEARBY PUMP ROOM v Q _ 150A/3P 150A/3P D w Q 600V 600V #3 EQUIPMENT #3 EQUIPMENT z Q GROUNDING GROUNDING w (1) 2"C W/(3) 2/0 CONDUCTOR CONDUCTOR w & #6 GRND 100AF / FN > U 100AT I\ (1) 2" C W/(3) 2/0 1 P & #6 GRND 15AF / 15AT / 15AF / 30AF / 30AF / AUTOMATIC 4-POLE 15AT ( 15AT 1 15T ( 30AT ( 30AT ( TRANSFER SWITCH cn >- 0 1P 1P 1P 2P 3P = w w z� 10MP 0P 100 HP 500 MCM 500 MCM = 0 0 U � � (1) 3/4"C W/ (2) #12 (1) 3/4"C W/ (2) #10 VN J & #12 GRND & #10 GRND w #3 EQUIPMENT CC J J Z w w GROUNDING G Q Q = w w CONDUCTOR a a � w w DRAWN: CWB DESIGNED: SMH G LOAD CHECKED: DPK ISSUE DATE 2/16/2024 ELECTRICAL ONE -LINE DIAGRAM REVISIONS E-501 NTS 2 GROUNDING DETAIL E-501 NTS JOB NO FACP0017 SHT TITLE ELECTRICAL ONE LINE DIAGRAM BID SET SHT NO 13 CI 39 16-FEB-2024 SHEET IS 22x34 ANSI D IF PRINTING 1 1 x 17 USE 50% SCALE FACTOR E-501 ti M M 00 m z 0 w Z iE w Om m (n w LL Q o Lu W � 0 U Z w 0 0 Q Q c0 o 0 M 0 ❑ ❑F W ,� �� 24078 �� ��- I STER�� �S1 SS10NAL z O W CD W 00 z a, W U)z °C � O z W O = CD U z J = C� W C/) � Q � Q D W C) � or w z = W > U Q cr ~ >- O W oc z W p O U U W DRAWN: CWB DESIGNED: SMH CHECKED: DPK ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITLE ELECTRICAL PANEL SCHEDULE DETAIL BID SET 16-FEB-2024 SHT NO 14 OF 39 SHEET IS 22x34 ANSI D IF PRINTING 1 1 x 17 USE 50% SCALE FACTOR E-60 I - PANEL NAME: L1 L-L VOLTAGE: 240 V BUS RATING: 100 AMPS PANEL LOCATION: PUMP ROOM L-N VOLTAGE: 120 V MAIN RATING 100 AMPS FED FROM: PUMP ROOM, PANEL H1 PHASES: 1 � FAULT RATING 10 kAIC FEEDER CIRCUIT: #VIA XFMR 1 WIRES: 3 FEEDER CABLE: (3) #2 & #8 GRND SPACES: 18 o c� Phase c� o ~ p CIRCUIT DIRECTORY A� B� C� Ov � J J � O A� B� C� CIRCUIT DIRECTORY p Y V Z Q Y O a O a Y Q Z U O m A B C m O J J 1 RECEPTACLES 180 R 15 1 X 1 15 L 310 LIGHTING 2 3 RECEPTACLES 360 R 15 1 X 2 30 H 2500 HEATER, GENERATOR ROOM 4 5 HEATER, PUMP ROOM 2500 H 30 2 X / H 2500 ----------- 6 7 ----------- 2500 H / X 8 9 X 10 11 X 12 13 X 14 15 X 16 17 X 18 A� B� CO NOTES: TOTAL CONNECT LOAD (VA): 2990 2860 5000 CALCULATED CODE DESCRIPTION CONNECTED LOAD x DEMAND FACTOR = DEMAND LOAD R GENERAL -USE RECEPT (FIRST 10KVA) 540 x 1.00 = 540 R GENERAL -USE RECEPT (OVER 10KVA) 0 x 0.50 = 0 L LIGHTING 310 x 1.25 = 387.5 M MOTORS &COMPRESSORS 0 x 1.00 = 0 LM LARGEST MOTOR LOAD 0 x 1.25 = 0 S DEDICATED RECEPTACLES 0 x 1.00 = 0 H HVAC ?� MECHANICAL EQUIPMENT 10000 x 1.00 = 10000 K KITCHEN EQUIPMENT 0 x 1.00 = 0 Z MISC. LOADS 0 x 1.00 = 0 TOTAL CONNECTED CALCULATED TOTAL CALCULATED LOAD (VA): 10,850 LOAD (VA): 10 928 AMPS (RMS): 45.53 ti c� co M z O w z 2 w OM m Cn w Qo W U � o UM W z Q0 o0 Q/' co co \` 00 0 ❑ V � z O_ j w � O W COo z � a, W �z O z W I= 0 z J = C a W C/� � Q Q � W w z = W > �J Q ~ >- O � W � zIM W C) O _ U) 0- C� J W DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS Page 1 of 2 JOB NO FACP0017 SHT TITLE TSI PUMP CONTROL DWG, CONTROL PANEL BID SET BOM 16-FEB-2024 SHT NO 15 ��,I 39 SHEET IS 22x34 ANSI D IF PRINTING 1 1 x 17 USE 50% SCALE FACTOR Technical Systems Inc Port Orchard Melcher Booster T&M Customer -Art Anderson and Associates Control Panel BOM City of Port Orchard Job Number - 8113 PartlD Qty Manufacturer Part Number Description Manufacturer Vendor MELCHER PUMP STATION RTU No. 10 127C 1 SCE-72XM6618 Flange Mount Disconnect Enclosure, Mild Steel, NEMA 3R/4/12, Dual Door, 72.00" x 65.75" x 18.00", with SCE-64P64 Subpanel, 2" Hole Seals Saginaw Saginaw 139J 1 P-R2-K2RF3-U450 Program Ports -Ethernet - RJ-45 CAT5 F/F connector - 120 VAC, Duplex GFCI - 3 Amp Breaker -Type 4X Saginaw Saginaw 141 A 1 AAM2F53Z11 AutomationDirect IEC limit switch, side rota Technical Systems Inc Port Orchard Melcher Booster T&M Customer -Art Anderson and Associates Control Panel BOM City of Port Orchard Job Number - 8113 PartlD Qty Manufacturer Part Number Description Manufacturer Vendor 510N 1 1769-L33ER CompactLogix Controller, Dual Ethernet w/DLR capability, 2MB Memory, 16 Local Modules, 512 I/O Expansion Modules, 32 Tasks Supported (Controllers are shipped with 1 GB SD card and can support up to 2GB SD card) Allen-Bradley North Coast Electric 512E 1 1769-PB4 PLC Power Supply, 24VDC, 4 amps @ 5VDC Allen-Bradley North Coast Electric 514C 2 1769-IQ16 Discrete Input Module, 16 Points, 10-30VDC, Sink or Source Allen-Bradley North Coast Electric 515G 1 1769-OW16 Discrete Relay Output Module, 16 Points, Non -Isolated Allen-Bradley North Coast Electric 516C 1 1769-IF8 Analog Input Module, 8 Channel, Voltage or Current (Note: this is a 2-slot width module) Allen-Bradley North Coast Electric 517D 1 1769-OF8C Analog Output Module, 8 Channel, Current, Allen-Bradley North Coast Electric 519H 1 1769-ECR End Cap Terminator, Right Allen-Bradley North Coast Electric 702A 1 140G-J6F3-D15 Molded Case Circuit Breaker, 150A, Thermal Magnetic, 65 kAIC Interrupt Rating, 3 Poles, 480VAC, J-Frame Allen Bradley North Coast Electric 702B 2 140G-J6F3-D20 Molded Case Circuit Breaker, 200A, Thermal Magnetic, 65 kAIC Interrupt Rating, 3 Poles, 480VAC, J-Frame Allen Bradley North Coast Electric 702C 2 140G-J-TLA13 Molded Case Circuit Breaker Terminal Lugs, Frame J, Qty 3, 1 x 14-1/0 AWG Allen Bradley North Coast Electric 702D 4 140G-J-MTL63 Molded Case Circuit Breaker Terminal Lugs, Frame J, Qty 3, 6 x 12-2 AWG Allen Bradley North Coast Electric 703A 1 140G-K6F3-D40 Molded Case Circuit Breaker, 400A, Thermal Magnetic, 65 kAIC Interrupt Rating, 3 Poles, 480VAC, K-Frame Allen Bradley North Coast Electric 703B 1 140G-K-TLA13 Molded Case Circuit Breaker Terminal Lugs, Frame K, Qty 3, 1 x 250-500 kcmil Allen Bradley North Coast Electric 703C 1 140G-K-MTL63 Molded Case Circuit Breaker Terminal Lugs, Frame-K, Multi Terminal Lug, Qty 3, 6x6-1/0(16-50) Allen Bradley North Coast Electric 705E 1 140G-K-FCXB03 Flange Mount Handle Assembly, 3' Cable, Non -Metallic Handle, Frame K Allen Bradley North Coast Electric 715B 1 4983-DS480-403 Surge Protector, Din Rail Mount, UL 1449 , 480V AC, 40kA (Phase), 3 Pole Configuration Allen Bradley North Coast Electric 720K 2 LP-CC-10 Fuse, 10 Amp, Class CC -Rejection, 600VAC/200kAIC, Current limiting, Time delay Bussmann Graybar 720M 3 LP-CC-15 Fuse, 15 Amp, Class CC -Rejection, 600VAC/200kAIC, Current limiting, Time delay Bussmann Graybar 725A 1 CCP2-2-30CC Fuse Holder, 2 Pole w/ Indicator, Class CC -Rejection, 600VAC/30 Amp, 200kA Interrupt Rating, Branch Circuit Protection Rated, Padlockable in Open/Off Position Bussmann Graybar 725B 1 CCP2-3-30CC Fuse Holder, 3 Pole w/ Indicator, Class CC -Rejection, 600VAC/30 Amp, 200kA Interrupt Rating, Branch Circuit Protection Rated, Padlockable in Open/Off Position Bussmann Graybar 732K 1 SP2000MQMJ Transformer, 2000 VA, Single Phase, 240/480 VAC Primary, 120/240 VAC Secondary Hammond Power Solutions Platt 733A 2 SPFG1 Transformer Finger Safe Guard, SP Type, 50-3000 VA sizes Hammond Power Platt Electric 736X 2 CRX0124AC Line Reactor, 3% Impedance, for 480 VAC 3 phase, 100 HP VFD, 124 A Max Hammond Power Platt Electric 737A 12 6920K52 Tin -Plated Aluminum Set Screw Lug, 1 Hole for 2 Wires, 14-2/0 AWG McMaster Carr McMaster Carr 780C 1 RM17TE00 Zelio, 3 Phase supply Control relay, 208 - 480VAC, sequence, phase failure, phase imbalance, voltage Schneider Graybar 900A 1 MXNCL4EN4GYNNS1 FIDUNN MCR Orbit LN4 Radio. Slot-1: L4E 406.1-470MHz. Slot-2: Cellular 4G LTE-A Americas, Carrier Profile = Verizon, US (FCC). GE MDS GE MDS 900B 2 POLTSX-NFF Surge Arrestor 0.698-2.7GHz DC Block Coax Protect, N-Female/N-Female connector -Cell PolyPhaser Talley 900C 2 CXTA24K-3 N-Male to SMA Male LMR240 Cable Assembly - 3 FT. Talley Talley 900D 1 POLIS-B50LN-C2 Bulkhead Mount Low Power Coax Protector, 125-1000 MHz w/ N-Female PolyPhaser Talley 900E 1 CXTA24G-3 3 Ft Cable Assy, LMR240 N-Male to TNC Male. Talley Talley 910A 1 n/a McCrometer Remote Mount Display (Existing Equipment) McCrometer McCrometer ti c� co M z 0 ix Z w w Om w Qo W U � Q U W Z Q/' M co \` DO 0 ❑ CU z j w � O W COo z Er a, w �z O z w � 0 z J = W U� � Q Q � W w z = w > �J Q ~ O � W � zEr W C) O _ U U w 75 DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS Page2of2 JOB NO FACP0017 SHT TITLE TSI PUMP CONTROL DWG, CONTROL PANEL BID SET BOM 16-FEB-2024 SHT NO 16 ��,I 39 SHEET IS 22x34 ANSI D 10 IF PRINTING 1 1 x 17 USE 50% SCALE FACTOR PC 0 r— M Cl) 00 >M z 0 W Z 2 -- — � m 65.75 1 42A 1 27C w Q g 900B 900C 900D 900E uJ iL Z a o� Q Q 0Cn u u u u s 0 156A 141A 141E _--------------_-F=r 1----------------------------I -� ---------------------------- -- F MELCHER BOOSTER PUMP STATION -------------_-_--_-----------_-- -- _-- _ ____________________________----- -T 1 - -- __ ` I ` I RTU NO. 10 o II I 11 I� 1 1 11 I I I 1 1 Hill I II 1 II ,III II 4 1prL F61 F61 G F616 11 I I I I I 1 I 11 I IIIII1 II I 11 III 705E 1 II II 11 I I II I I 1 I 1 I 1 11 III I Ilo IIII u Ln II I I 1 1 IIII III � II II II I I I 1 I 11 III I 11° IIII v u� v � 1 II 1 1 II 1 II 1 F61 1 II II 1 1 11 1 1 I I I 1 1 I 11 III II 11 Hill 1 39J 1 44D I II 1 I II 0 oa..,o 0 1 1 II I I 1 1 I Hill 11 Hill 11 11 I I I io 1 11 IIII 11 IIII II I Hill z 452D II 1 II Fol ,raO G 11 II ®--- ---® O I� 11 11 111I 11 IIII O II 11 1 1 1 1 1 I II 1 1 11 ._ ,r II 1 1 1 1® ®� 11 IIII \ w I II 1 11 R R I I r� 1 1 I 1 1 1 IIII 1 I111 1 4 3 D O w Co 11 1 I II -® �� I —I 1 1 1 0 v I 1 1 1 I —I Hill � III z w � 91 OA 1 fH. IIII 11_ °IIII II 1 111 z „ 72 1 II 1 I I_ I1 I I 11 1 JI11 1 1 1 IIII H IIII IIII O zII 1 I II 1 I I I I 1 I 11 1 I II TT IIII I O _ II 1 II 1 1 1 1 1 1 111 1 Hill~ z 1 1 II 1 11 II 1 1 1 1 1 1 1 II Hill Hill Q J U„ 1 I II 1 11 11 I I 11 1 1 1 I 1 11 IIII 11 Hill � G Q G 56" 1 II 1 1 1 1 �� Hill Hill C 1 I II 11 I I I I 11 IIII G 1 1 11 1 IIII W 0 1 1 11 1 1 11 I I 11 I I 1 1 Hill 11 Hill 1 1 11 1 IIII z Q 1 11 1 11II 1 11 I I 1 1 11 Hill Hili 11 Hill �� 44 w W = W > U 1 11 1 IIII Q 1 I II 1 I 11 1� II I I I Hill 11 IIII 156B O 1 I II 1 II 1 1 II II � � II 1 II II I I 1 1 I I 1 1111 11 IIII Hill W z 1 I II 1 II 1 II o11 �"� II I II1 1 I I 11 III Hill O 1 1 II �II 1 I 11 II Il0 I❑ II II I I I 11 IIII Hill — U) I Il 1 II II 1 I I I 11 Hill J I 11 1 II 11 1 II I I1 �—L_____________� II V 1 I I I I I 11 Hill IIII Ip I UJI C G ° I 1 I� 1°------------------------------ I oj L-------------------------------- — -------------------------------- — —11 ------------------------------------ - ------------------- -------------- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS DEPTH OF PANEL = 18" XXX BOM ITEM NUMBER JOB NO FACP0017 REV DESCRIPTION INIT / DATE LISTING Technical Systems Inc. CUSTOMER ART ANDERSON & EN / PM / CHK KD/AP/AP MELCHER BOOSTER PUMP STATION UPGRADE DATE CREATED 12/01 /2022 REV. 1.1 sHT TITEE UL508 1.0 SUBMITTAL/JW 06/06/23 ❑ S/N 2303 196TH LYNNWOOD, WA. ST. S.W. 98036 ASSOCIATES MELCHER PUMP STATION RTU NO. 10 TSI PUMP CONTROL DRAWN JOB NO. ❑ S�N98A (425) 775-5696 RJC 81 1 3 DWG RTU 10-10.01, PANEL LAYOUT 1.1 RESUBMITTAL/JW 07/06/23 CITY OE PORT ORCHARD, WA PANEL LAYOUT DWG. N0. RTU 1 0-10.01 ❑ OTHER N I- NC 17 OF 39 BID SETI 16-FEB-2024 PC- 1p oo,: r- M Cl) 00 >M z 0 W z 2 W 000 00 C ♦ W i a O W LL UL? H o Q� z a 7 Co 0 Q Q CD 236A 237A 405A 900A 900C 715B 725A 720K 725B 720M 780C 732K 733A 127C 405C ...... o 0 b b 0 a 0 a*e o 0 o LLNwc OF II M WIRE I C702AS702C • 00 ❑ g g O 9 9® 9 CONTROL TRANSFORMER LJ E N D N G 436D 436B W �0 0 0 0 0 0 0 0 0 RADIUS U 0 �0 AREA i tea; 703A 703B 703C U 200B 201 B 202A 203A I ~ ....... 241 H 1l 1l I I ��; 'D[l i z e 307C 307D FRAAM mo Q 241 E 241 K 260A W o °o p w co ®° 1= 00 210A 221 D O° °® ®1 !® I Lu p� U) z ®° °® 702B 702D rr O 241 C ®° °® o° oo z w o° to O U z 3 0 7 D 3 0 7 B `° o•® o o o•® o T Lu �1^ h 210B 221 D . � G Q mo mo 736X 737A 3: FRME FROM Q _ ° Z) Lu 0 21 OA 221 B ::) zQ w w = Lu > U Q M 0 0 (n O Ic 0 0 LJJ w z� 21OA 221ALu L9 o o = 00 U J D] 0 o W 0 [C O DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 BACK PAN REVGONS XXX BOM ITEM NUMBER JOB NO REV DESCRIPTION INIT DATE LISTING CUSTOMER EN / PM / CHK DATE CREATED REV. FACP0017 / Technical Systems Inc. ART ANDERSON & KD/AP/AP MELCHER BOOSTER PUMP STATION UPGRADE 12/01 /2022 1.1 sHT TiTEE ❑ UL508 2303 196TH ST. S.W. 1.0 SUBMITTAL/JW 06/06/23 S/N LYNNWOOD, WA. 98036 ASSOCIATES DRAWN M ELC H ER PUMP STATION RTU NO. 10 JOB NO. TSI PUMP CONTROL 1.1 RESUBMITTAL/JW 07/06/23 ❑ UL698A (425) 775-5696 RJC 81 1 3 TU 10-10.04, 1DWG DWG RN LAYOUT BACKPAN LAYOUT ❑ OTHER CITY OF PORT ORCHARD, WA DWG. N0. RTU 1 0-10.04 SHT NO 18 OF 39 BID SET 16-FEB-2024 11111111/ e� 1` M Co aD >M z 0 W Z 2 LLJ 0Co CoC ♦ lil i Q O U � W NHN o Q� I.f. z d o 0606 CO 510N 514C 514C 515G 512E 516C 517D 519HLo u u u V) 6 dn 0 4 8 12 0 4 8 12 —1 oQ� o 0000 0000 o000 15 o 000 0 ("� RUN® ®N9 d 2 6 1014 d 2 6 1014 At .1 /. D DKo z o 0 0 o z 2 0 0 o d FORM® ® U o 0 0 o U o 0 0 0 D no ® ®ua 2 0 O OK ®SD Q 24 VDC Sink/Source Q 24 VDC Sink/Source b ANALOG 0 0 p 1 1 2 2 1 z 3 3 0 4 4 2 _ 5 5 6 6 3 A� Afib -Brady 7 7 W 8 8 4 0 w� 9 9 z Co Q� 0 0 5 W �.! J 11 11 � Cr z _ 2 2 6 r 0 3 3 Z WW ®v go-yp 4 4 O 2 V 2Q 5 5 U z J = C� W U) SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 0 Q Q W 0- w z = RACK 1 LU Q ~ 0 W CC z rr W p 0 _ �0- U J W DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS XXX BOM ITEM NUMBER JOB NO REV DESCRIPTION INIT DATE LISTING CUSTOMER EN / PM / CHK DATE CREATED REV. FACP0017 / Technical Systems Inc. ART ANDERSON & KD/AP/AP MELCHER BOOSTER PUMP STATION UPGRADE 12/01 /2022 1.1 SHT TiTEE ❑ UL508 2303 196TH ST. S.W. 1.0 SUBMITTAL/JW 06/06/23 S/N LYNNWOOD, WA. 98036 ASSOCIATES DRAWN M ELC H ER PUMP STATION RTU NO. 10 JOB NO. TSI PUMP CONTROL 1.1 RESUBMITTAL/JW 07/06/23 ❑ UL6198A (425) 775-5696 RJC 81 1 3 DWG RACK L AYOUT10.06, PLC ❑ OTHER CITY OF PORT ORCHARD, WA PLC RACK LAYOUT DWG. RTU 1 0-1 0.06 SHT NO 19 01 39 BID SET 16—FEB-2024 � � � U 0 Q � 0 4 8 12 o 0 0 Cl 1 5 9 13 0 0 0 0 2 6 10 14 0 0 0 0 o 0 0 0 Relay 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 a z � OKo ANALOG 0 1 2 3 4 5 6 7 ti M Co 00 >M z 0 W z 2 W O CoVCl) W 364D 364C W 2 CONTROL POWER HIGH PRESSURE OK RTU OK LOW PRESSURE GENERATOR RUNNING - o Q w z d O O 0w000() M CO 06 e 356D PROCESS STOP ENABLE DISABLE OFF 356B OFF z ///-- HAND AUTO HAND AUTO O 0 9 W � O � W a) 357B LZ p= � z 364B z Cr O ALARM RESET RUNNING RUNNING W �i� O = (V U z J 0 G G = W U) 0 Q W C) 364C 0- =) rr FAIL FAIL Z '� W > U Q R R ~ >- O U)W� CC z rr _ � O U � � 358A J SPEED SPEED W DRAWN: --- DESIGNED: --- MIN MAX MIN MAX CHECKED: --- ISSUE DATE 2/26/2024 REVISIONS XXX BOM ITEM NUMBER JOB NO FACP0017 REV DESCRIPTION INIT / DATE LISTING Technical Systems Inc. CUSTOMER ART ANDERSON & EN / PM / CHK KD/AP/AP MELCHER BOOSTER PUMP STATION UPGRADE DATE CREATED 12/01 /2022 REV. 1.1 SHT TiTEE UL508 ❑ S/N 2303 196TH ST. S.W. LYNNWOOD, WA. 98036 ASSOCIATES M ELC H ER PUMP STATION RTU NO. 10 TSI PUMP CONTROL 1.0 SUBMITTAL/JW 06/06/23 DRAWN JOB NO. ❑ UL6198A (425) 775-5696 RJC 81 1 3 DWG RTU 10-10.09, CONTROLS DETAIL 1.1 RESUBMITTAL/JW 07/06/23 CITY OE PORT ORCHARD, WA CONTROLS DETAIL DWG. RTU 1 0-1 0.09 ❑ OTHER SHT No 20 01 39 BID SET F'16-FEB-2024 ipc- ooe PL ti M Co 00 >M z 0 W z 2 W OCo CoC ♦ W W U L? 11 H 0 Q w z a 00 co 3/8" WHITE LETTERS ON A BLACK BACKGROUND 1 .5 MELCHER O BOOSTER PUMP STAT0N O RTU NOo 10 UU� z O w(D > 1 .75" w cY) z 00 z M 1 /8 WHITE LETTERS ON A BLACK BACKGROUND � Cn z 0.75" 0 INTRUSION 0 0 PUMP 1 O O PUMP 2 0 z wo0 _ (.D U z J = W C� C/) � Q 3: Q W C) 0- =) rr w z = w > U Q ~ O w CC z rr w p O _ C/)0- U J w DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS NOTE: SCREW DOWN ALL NAMEPLATES WITH STAINLESS STEEL SCREWS. JOB NO FACP0017 REV DESCRIPTION INIT / DATE LISTING Technical Systems Inc. CUSTOMER ART ANDERSON & EN / PM / CHK KD/AP/AP MELCHER BOOSTER PUMP STATION UPGRADE DATE CREATED 12/01 /2022 REV. 1.1 SHT PTEE UL508 1.0 SUBMITTAL/JW 06/06/23 ❑ S/N 2303 196TH ST. S.W. LYNNWOOD, WA. 98036 ASSOCIATES MELCHER PUMP STATION RTU NO. 10 TSI PUMP CONTROL DRAWN JOB NO. ❑ UL6198A (425) 775-5696 RJC 81 1 3 DWG RT 1010.1LAYOUT 1.1 RESUBMITTAL/JW 07/06/23 CITY OE PORT ORCHARD, WA NAMEPLATE LAYOUT DWG. RTU 1 0-1 0.1 0 ❑ OTHER SHT No 21 OF 39 BID SET F'16—FEB-2024 ipc— 00 ti M Co 00 >M z 0 W Z 2 W OCo CoC ♦ W Q O i U � W o QI-- NHN I.f. Z d o� CO Mco MEECHER PUMP STAT ON RTU 1 0 CONTROL PANEL NETWORK DIAGRAM 4 CELLULAR ANTENNA #1 -- QTY:1 LMR-240------- QTY:1 LIGHTNING ARRESTOR LMR-240 LMR-240 CELLULAR ANTENNA #2 QTY:1 LMR-240--- LIGHTNING ARRESTOR QTY:1 LMR-240 LMR-240 RADIO OIT RADIO ANTENNA QTY:1 LMR-400—— LIGHTNING ARRESTOR QTY:1 LMR-400 LMR-400 rr. v �, D D rn QTY:1 rn QTY:1 QTY:1 QTY:1 ETHERNET SWITCH GRACEPORT CAT6 ES 1 CAT PLC DWG 20.30 z 0 Qo u Q u > Lu CD 0 w � Qo QoIr z z Cr O w O = J I I — Q = w U) U U ^ Q I I ,., w 0 w z= Q Q w I I w > U QTY:1 --Ct) (:t>- QTY:1 Q Er VFD M1 VFD M2 >- O z � Ir °C w U C/) 0- w 75 DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 REV DESCRIPTION INIT / DATE LISTING Technical Systems Inc. CUSTOMER ART ANDERSON & EN / PM / CHK KD/AP/AP MEECHER BOOSTER PUMP STATION UPGRADE DATE CREATED 12/01 /2022 REV. 1 SHT riTEE 8 1.0 SUBMITTAL/JW 06/06/23 S/N LYNONWOODT WA. T98036 ASSOCIATES NETWORK PANEL (NP—BLWR) .1 TSI PUMP CONTROL DRAWN JOB NO. ❑ S/N98A (425) 775-5696 RJC NETWORK OVERVIEW 81 1 3 DWG RTU-10-20.01, OVERVIEW NETWORK DIA 1.1 RESUBMITTAL/JW 07/06/23 CITY OF PORT ORCHARD, WA OVERVIEW NETWORK DIAGRAM DWG. RTU 1 0-20.01 ❑ OTHER S i- No 22 OF 39 BID SETT 16—FEB-2024 PC- "o ETHERNET SWITCH ES1 ti M Co 00 M >Q Z 0 w 7- w Co z 0 Cn w W w z Q Q ago ES1 PANEL ETHERNET SWITCH z DESTINATION DEVICE O PORT# TYPE NETWORK DESCRIPTION CABLE LABEL DESCRIPTION DRAWING REF PORT ~ 1 CAT6 P LC P LC P LC 20.01 1 > O w w CY) 2 CAT6 OIT OIT OIT 20.01 1 z 00 M w 3 CAT6 RADIO RADIO RADIO 20.01 1 I= (n z 4 CAT6 VARIABLE FREQUENCY DRIVE - M 1 VFD-M 1 VARIABLE FREQUENCY DRIVE - MI 50.01 1 z w O 5 CAT6 VARIABLE FREQUENCY DRIVE - M2 VFD-M2 VARIABLE FREQUENCY DRIVE - M2 50.02 1 = CD U z 6 CAT6 GRACEPORT GP GRACEPORT 20.01 1 J = w 7 CAT6 C� (/) Q 8 CAT6 0- Q GB1 w o G132 0- =) rr w z = w > U Q rr ~ O CC w z rr w p O _ U C/)0 J w REV DESCRIPTION/INIT DATE LISTING Technical Systems Inc. 2303 196TH ST. S.W. LYNNWOOD, WA. 98036 (425) 775-5696 CUSTOMER ART ANDERSON & ASSOCIATES EN / PM / CHK KD/AP/AP MELCHER BOOSTER PUMP STATION UPGRADE M ELC H ER PUMP STATION RTU NO. 10 ETHERNET SWITCH (ES-1 � NETWORK SWITCH DATE CREATED 12/01 /2022 REV. 1.1 ❑ UL508 S/N 1.0 SUBMITTAL/JW 06/06/23 DRAWN RJC JOB NO. 81 1 3 ❑ UL6198A 1.1 RESUBMITTAL/JW 07/06/23 CITY OF PORT ORCHARD, WA DWG. N0. RTU 1 0-20.30 ❑ OTHER DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITLE TSI PUMP CONTROL DWG RTU-10-20.30, NETWORK SWITCH BID SET 16-FEB-2024 SHT NO 23 OF 39 ti M Co Co >M z 0 w Z 2 w OCo Co Cl) w 6L Q o W U H 0 Q� zo0 M CO V �i V cn C! Z O w W 00 Z 00 LJJ � Z � Cr O Z W U z J = (� LJJ U) Q Q W 0— w Z = w > U Q Er ~ >- O � w Z� W C) O U J w DRAWN: --- DESIGNED: --- CHECKED: --- SSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITEE TSI PUMP CONTROL DWG RTU-10-30.01, 480V POWER DIST DIA SHT No 24 OF 39 BID SET 16—FEB-2024 p C-0 It RTU 1 0 CB -MAIN 480 VAC �--- ti M Co Co >M z 0 w z 2 w 0 � Co (n ui 6L Q o W U � w z Q/' M CO00 u � V UO C! z O W O W o0 z a, W � z z w 0 � U z J = � W � Q Q _ W 0- w z = W > U Q Er W zrr W p 0 _ (n 0- U J W DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2025 REVISIONS 40 JOB NO FACP0017 SHT TITEE TSI PUMP CONTROL DWG RTU-10-40.101B, RACK 1, SLOT 01—WIRING DIA SHT No 28 OF 39 BID SET 16—FEB-2024 jpC— 0 1 FIELD RTU 1 0 (CONTINUED FROM DWG 40.101A) FROM 24VDC UPS POWER DWG RTU10-30.20 16 Pt. 24VDC DISCRETE INPUT MODULE GENERATOR U24P U24C RACK 1 , SLOT 01 XX DF.101.08 (0.5A) DF.101.08 U24P 1769-IQ16 XX D1.101.08 D1.101.08 D1.101.08 IN 8 GENERATOR RUNNING XX — — — — — — — — — — — — D1.101.09 — — — — — — — — — D1.101.09 — — — — — — D1.101.09 IN 9 GENERATOR NIN XX D1.101.10 D1.101.10 D1.101.10 IN 10 GENERATOR FAULT XX D1.101.11 D1.101.11 D1.101.11 IN 11 GENERATOR LOW LEVEL XX — — — — — — — — — — — — D1.101.12 — — — — — — — — — D1.101.12 — — — — — D1.101.12 IN 12 GENERATOR FUEL LEAK (0.5A) DF.101.13 U24P n D1.101 .13 D1.101 .1 3 IN 1 3 SPARE DF.101.14 (0.5A) U24P � PS-1 � — — o— — — — — — — — — — — — — — — — — D1.1 01 .1 4 — — — — — — — — — D1.1 01 .1 4 — — — — — — D1.1 01 .1 4 IN 14 SUCTION WATER PRESSURE LOW DF.101.15 (0.5A) U24P � PS-2 D1.101.15 n D1.101.15 D1.101.15 IN 15 DISCHARGE WATER PRESSURE HIGH U24C DC COM 2 U24P U24C REV DESCRIPTION/INIT DATE LISTING Technical Systems Inc. 2303 196TH ST. S.W. LYNNWOOD, WA. 98036 (425) 775-5696 CUSTOMER ART ANDERSON ASSOCIATES & EN / PM / CHK KD/AP/AP ME�CHER RACK BOOSTER RTU DISCRETE 1 , SLOT PUMP STATION UPGRADE 10 (RTU 10) INPUT MODULE 01 — WIRING DIAGRAM DATE CREATED 12/01 /2022 REV. 1 .1 ❑ UL508 S/N 1 .0 SUBMITTAL/JW 06/06/23 DRAWN RJC JOB N0. 8113 ❑ 5�698A 1.1 RESUBMITTAL/JW 09/19/23 CITY OF PORT ORCHARD, WA DWG. No. RTU 1 0-40.1 01 B ❑ OTHER ti M Co Co >M z 0 w z 2 w 0 � Co (n ui 6L Q o W U H 0 Q� w z o0 Q/' M CO \` u � V UO C! z O W CD W 00 z a, W Igh � z z Cr IRV = � U z J = � W � Q Q W w z = w > U Q cn W CC z� w p 0 _ (n U J w19111 DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITEE TSI PUMP CONTROL DWG RTU-10-40.102A, RACK 1, SLOT 02—WIRING DIA SHT No 29 OF 39 BID SET 16—FEB-2024 PC-01 FIELD RTU 1 0 FROM 24VDC UPS POWER DWG RTU 10-30.20 16 Pt. 24VDC DISCRETE INPUT MODULE U24P HS-02 U24C RACK 1 , SLOT 02 OFF 1769-IQ16 AUTO HAND ! t 14, _\ � OX � D1.102.00 IN 0 PUMP N0. 2 IN HAND ' � OOX D1.102.01 IN 1 N AUT00. 2 LT1 -M2 G U24P / \ D1.102.02 D1.102.02 IN 2 PUMP N0. 2 RUNNING LT2-M2 SEE DWG RTU 10-50.02 R n D1.102.03 D1.102.03 IN 3 PUMP N0. 2 FAILED n U24C (0.5A) DF.102.04 U24P n D1.102.04 D1.102.04 IN 4 SPARE DF.102.05 (0.5A) U24P � LS-SV2 L D1.102.05 n D1.102.05 D1.102.05 IN 5 SOLENOID VALVE N0. 2 OPEN (0.5A) DF.102.06 U24P n D1.102.06 D1.102.06 IN 6 SPARE PROCESS STOP PB-1 D1.102.07 I N 7 PROCESS STOP ACTIVE CR VCR U24C DC COM 1 U24P U24C (CONTINUED TO DWG 40.102B) REV DESCRIPTION/INIT DATE LISTING Technical Systems Inc. 2303 196TH sT. S.W. LYNNWOOD, WA. 98036 (425) 775-5696 CUSTOMER ART ANDERSON ASSOCIATES 8c EN / PM / CHK KD/AP/AP MELCHER RACK BOOSTER PUMP STATION UPGRADE RTU 1 0 (RTU 1 0) DISCRETE INPUT MODULE 1 , SCOT 02 — WIRING DIAGRAM DATE CREATED 12/01 /2022 REV. 1 .1 ❑ UL508 S/N 1 .0 SUBMITTAL/JW 06/06/23 DRAWN RJC JOB N0. 81 1 3 ❑ S�N98A 1.1 RESUBMITTAL/JW 07/06/23 CITY OF PORT ORCHARD, WA DRTU 10-40.102A ❑ OTHER ti M Co Co >M z 0 w z 2 w 0 � Co (n ui 6L Q o W U w z Q/' M CO00 u V UO C!40 --C� ko-- Z 0 W O W o0 z a, W � z z w 0 = � U z J = � W � Q � Q _ 4v-+� �0— W 0- w z = W > U � Q � ~ >- O cn W cc zrr w p 0 _ (n 0- U J W DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITEE TSI PUMP CONTROL DWG RTU-10-40.102B, RACK 1, SLOT 02—WIRING DIA SHT No 30 OF 39 BID SET 16—FEB-2024 PC-01 FIELD RTU 1 0 (CONTINUED FROM DWG 40.102A) FROM 24VDC UPS POWER DWG RTU 10-30.20 16 Pt. 24VDC DISCRETE INPUT MODULE AUTOMATIC TRANSFER SWITCH U24P U24C RACK 1 , SLOT 02 XX ------------ DF.102.08 --------------- (0.5A) DF.102.08 U24P 1769-IQ16 XX — — D1.102.08— — — — — — — — — D1.102.08 D1.102.08 IN 8 AUTOMATIC TRANSFER SWITCH POSITION EMERGENCY DF.102.09 (0.5A) DF.102.09 U24P XX ------------ D1.102.09 --------------- D1.102.09 D1.102.09 IN 9 AUTOMATIC TRANSFER SWITCH POSITION NORMAL PFR D1.102.10 IN 10 RTU 10 CONTROL PANEL PHASE FAILURE ALARM RESET PB-2 � D1.102.1 1 IN 11 ALARM RESET DC UPS 1 2 D1.102.12 IN 12 24VDC POWER OK 3 4 D1.102.13 IN 13 24VDC POWER ON BATTERY ENABLE ! _\== � DISABLE �XO D1.102.14 IN 14 RTU 10 CONTROL PANEL INTRUSION ENABLE/DISABLE YS-01 D1.102.15 IN 15 RTU 10 CONTROL PANEL INSTRUSION U24C DC COM 2 U24P U24C REV DESCRIPTION/INIT DATE LISTING Technical Systems Inc. 2303 196TH sT. S.W. LYNNWOOD, WA. 98036 (425) 775-5696 CUSTOMER ART ANDERSON 8c ASSOCIATES EN / PM / CHK KD/AP/AP MELCHER RACK BOOSTER PUMP STATION UPGRADE RTU 1 0 (RTU 1 0) DISCRETE INPUT MODULE 1 , SCOT 02 — WIRING DIAGRAM DATE CREATED 12/01 /2022 REV. 1 .1 ❑ UL508 S/N 1 .0 SUBMITTAL/JW 06/06/23 DRAWN RJC JOB NO. 81 1 3 ❑ S�N98A 1.1 RESUBMITTAL/JW 07/06/23 CITY OF PORT ORCHARD, WA DRTU 10-40.102B ❑ OTHER ti M Co Co >M z 0 w z 2 w 0 � Co (n ui 6L Q o W U w z o� 00 u r. CR V UO C! H � 40 01 � kO— Z O jW co � W Co 00 z � � W Ir � Z z Cr = U z 0d I -MAF. 10 J = C� W C/) � Q Q _ W C) � rr VN w z = W > U Q Er ~ >- O W CC z� W C) O _ (n 0- U J W DRAWN: --- DESIGNED: --- CHECKED: — — — ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITLE TSI PUMP CONTROL DWG RTU-10-40.103A, RACK 1, SLOT 03—WIRING DIA SHT No 31 OF 39 BID SET 0 1 M;F 16—FEB-2024 IF'C- y RTU 1 0 FIELD RELAY 16 OUTPUT Pt. MODULE FROM 24VDC UPS POWER DWG RTU 10-30.20 RACK 1 , SLOT 03 U24P U24C 1769-OW16 VAC-VDC 1 U24P PUMP N0. 1 RUN COMMAND OUT 0 D0.103.00 CR 103.00 SEE DWG RTU 10-50.01 120VAC POWER FROM DWG RTU 10-30.10 PUMP N0. 2 RUN COMMAND OUT 1 D0.103.01 103 01 SEE DWG RTU 10-50.02 AC05A N1 HS-1 OFF HAND ! t � AUTO X00 N1 SV-1 SOLENOID CONTROL VALVE PUMP N0. 1 OPEN COMMAND OUT 2 D0.103.02 CR 103.02 CR.103.02 (2A) AF.103.02 � � J HS-2 OFF AUTO HAND ! t Ile X00 SV-2 SOLENOID CONTROL VALVE PUMP N0. 2 N COMMAND OUT 3 D0.103.03 CR 103.03 CR.103.03 (2A) � � ti M Co Co >M z 0 w z 2 w 0 m (n ui 6L Q o W U w z o0 Q/' M CO00 u � V UO C! H 4v---Cd Z 0 LJJ CD LJJ 00 z C0 LJJ � Z z Cr 0 O = CD � U z J = (� LJJ C/) Q Q _ Lu 0 0- � Cr F71w z = w > U —01 Q Cr ~ O C/) L U CC z rr LU p O _ �� U J —01 W DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITEE TSI PUMP CONTROL DWG RTU-10-40.103B, RACK 1, SLOT 03—WIRING DIA SHT No 32 OF 39 BID SET 16—FEB-2024 PC-01 RTU 1 0 FIELD (CONTINUED RELAY FROM DWG 40.103A) 1 6 Pt. OUTPUT MODULE FROM 24VDC POWER DWG RTU 10-30.20 24VDC UPS POWER FROM DWG RTU 10-30.20 RACK 1, SLOT 03 U24P U24C U24P U24C 1769-OW16 VAC-VDC 2 U24P LT-2 RTU 10 CONTROLEMETRY OK OUT 8 D0.103.08 CR 103.08 CR. 103.08 \ CR.103.08 G U24P / / \ U24C LT- 3 DISCHARGE WATER HIGH PRESSURE OUT 9 D0.103.09 CR 103.09 CR. 103.09 \ CR.103.09 R / U24C U24P / \ LT- 4 SUCTION WATER LOW PRESSURE OUT 10 D0.103.10 CR 103.10 CR.103.10 \ CR.103.10 R / U24C U24P / \ GENERATOR RUNNING (FUTURE) OUT 11 D0.103.11 CR 103.11 CR.103.1 1 LT-5 � ,,� CR.103.11 \ R U24P / / \ U24C CR.103.12A SPARE OUT 12 D0.103.12 CR CR.103.12 103.12 CR.103.12B CR.103.1 3A SPARE OUT 13 D0.103.13 CR CR.103.13 103.13 CR.103.13B CR.103.1 4A SPARE OUT 14 D0.103.14 CR CR. 103.14 103.14 CR.103.14B CR.103.1 5A SPARE OUT 15 D0.103.15 CR CR.103.15 103.15 CR.103.15B U24P U24C REV DESCRIPTION/INIT DATE LISTING Technical Systems Inc. 2303 196TH sT. S.W. LYNNWOOD, WA. 98036 (425) 775-5696 CUSTOMER ART ANDERSON 8c ASSOCIATES EN / PM / KD/AP/AP CHK MELCHER RACK BOOSTER PUMP STATION UPGRADE RTU 1 0 (RTU 1 0) RELAY OUTPUT MODULE 1 , SCOT 03 — WIRING DIAGRAM DATE CREATED 12/01 /2022 REV. 1 .1 ❑ UL508 S/N 1 .0 SUBMITTAL/JW 06/06/23 DRAWN RJC JOB N0. 81 1 3 ❑ S�N98A 1 .1 RESUBMITTAL/JW 07/06/23 CITY OF PORT ORCHARD, WA DRTU 10-40.103B ❑ OTHER ti M Co Co >M z 0 w z 2 w 0 � Co (n ui 6L Q o W U z o� Q /' M CO \` W4 u u UO C! Z 0 W co Y 0 W 00 z � M Er W � z z Cr 0 0 = 0 � U z J = � W � Q Q _ W w z = W > U Ll Q Er ~ O cn W zrr W p O U J W IRV DRAWN: --- DESIGNED: --- CHECKED: --- Ll SSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITEE TSI PUMP CONTROL DWG RTU-10-40.104A, RACK 1, SLOT 04-WIRING DIA SHT No 33 OF 39 BID SET 16-FEB-2024 PC-01 FIELD RTU 1 0 FROM 24VDC UPS POWER DWG RTU 10-30.20 8 Pt. ANALOG INPUT MODULE U24P U24C RACK 1, SLOT 04 1769-IF8 (DIFFERENTIAL CURRENT WIRING) (0.25A) U24P DF.104.00 ®V in 0+ � n � A1.1 04.00+�1 SEE DWG RTU 10-50.01 4-20mA � n A1.1 04.00- � � A1.1 04.00+ n I in 0+ V/I in 0- PUMP N0. 1 SPEED FEEDBACK 0-100% A1.1 04.00- U U24C ANLG COM GND (0.25A) U24P DF.1 04.01 ®V in 1 + � n � A1.1 04.01 +�1 SEE DWG RTU 10-50.02 4-20mA � n A1.1 04.01 - � � A1.1 04.01 + n I in 1 + V/I in 1 - PUMP N0. 2 SPEED FEEDBACK 0-100� A1.1 04.01 - n U24C ANLG COM GND (0.25A) U24P DF.104.02 ®V in 2+ n A1.104.02+ n � A1.104.02+ n I in 2+ SPARE A1.104.02- 4-20mA � A1.104.02- V/I in 2- U U24C GND ANLG COM (0.25A) U24P DF.104.03 ®V in 3+ n A1.1 04.03+ n � A1.1 04.03+ n I in 3+ SPARE A1.104.03- 4-20mA � A1.104.03- V/I in 3- U U24C GND ANLG COM NOTE: REMOVE JUMPER FOR 4-WIRE DEVICE. U24P U24C (CONTINUED TO DWG 40.104B) REV DESCRIPTION/INIT DATE LISTING Technical Systems Inc. 2303 196TH sT. S.W. LYNNWOOD, WA. 98036 (425) 775-5696 CUSTOMER ART ANDERSON 8c ASSOCIATES EN / PM / CHK KD/AP/AP MELCHER BOOSTER PUMP STATION UPGRADE RTU 1 0 (RTU 1 0) ANALOG INPUT MODULE RACK 1 , SCOT 04 - WIRING DIAGRAM DATE CREATED 12/01 /2022 REV. 1 .1 ❑ UL508 S/N 1 .0 SUBMITTAL/JW 06/06/23 DRAWN RJC JOB N0. 81 1 3 ❑ S�N98A 1.1 RESUBMITTAL/JW 07/06/23 CITY OF PORT ORCHARD, WA DRTU 10-40.1 04A ❑ OTHER ti M Co Co >M z 0 w Z 2 w 0 � Co (n ui 6L Q o W U N� Q U � LL z d o Q 0 MCD u V UO C! Z 0 W Y 0 W 00 z � M Er W � z z Cr 0 0 = 0 � U z J = � W � Q Q _ W 0 w z = W > U Ll Q Er ~ O cn W zrr W p O U J W Igh DRAWN: --- DESIGNED: --- CHECKED: --- Ll SSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITEE TSI PUMP CONTROL DWG RTU-10-40.104B, RACK 1, SLOT 04—WIRING DIA SHT No 34 OF 39 BID SET 16—FEB-2024 C-020 FIELD RTU 1 0 (CONTINUED FROM DWG 40.104A) FROM 24VDC UPS POWER DWG RTU 10-30.20 8 Pt. ANALOG INPUT MODULE U24P U24C RACK 1, SLOT 04 (2A) 2 DF.FIT1 FI 1 n U24C 1 769-IF8 (DIFFERENTIAL CURRENT 4 ti M Co Co >M z 0 w z 2 w 0 � Co (n ui 6L Q o W U H 0 Q� z o� M CO00 u u UO C! Z O > w co O W o0 z a, W � z z Cr 0 O = CD � U z J = � W � Q 0- 1-- 3: Q _ W C) 0- � rr Y— w z = w > U Q Er ~ O w CC z rr w p O _ �0- U J w Y— DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITEE TSI PUMP CONTROL DWG RTU-10-40.105A, RACK 1, SLOT 05—WIRING DIA SHT No 35 OF 39 F' BID SET 16—FEB-2024 PC-02 RTU 1 0 FIELD 8 Pt. ANALOG OUTPUT MODULE FROM 24VDC UPS POWER DWG RTU 10-30.20 RACK 1 , SLOT 05 U24P U24C 1769-OF8C +24VDC U24P DC NEUT U24C PUMP N0. 1 SPEED COMMAND 0-100% I OUT 0+ ANLG COM n A0.105.00+ � � 4-20mA n (0.25A) DF.105.00 A0,105.00- n � 1 I I SEE DWG RTU 10-50.01 A0.105.00- PUMP N0. 2 SPEED COMMAND 0-100% I OUT 1 + ANLG COM n A0.105.01 + � � 4-20mA n (0.25A) DF.1 05.01 A0.105.01 n � 1 SEE DWG RTU 10-50.02 A0.105.01 - SPARE I OUT 2+ n A0.105.02+ � n (0.25A) DF.105.02 ANLG COM A0.105.02- � 4-20mA A0.105.02-n SPARE I OUT 3+ n A0.105.03+ � n (0.25A) DF.105.03 ANLG COM A0.105.03- � 4-20mA A0.105.03- n U24P U24C (CONTINUED TO DWG 40.105B) REV DESCRIPTION/INIT DATE LISTING Technical Systems Inc. 2303 196TH sT. S.W. LYNNWOOD, WA. 98036 (425) 775-5696 CUSTOMER ART ANDERSON ASSOCIATES 8c EN / KD/AP/AP PM / CHK MELCHER BOOSTER PUMP STATION UPGRADE RTU 1 0 (RTU 1 0) ANALOG OUTPUT MODULE RACK 1 , SCOT 05 — WIRING DIAGRAM DATE CREATED 12/01 /2022 REV. 1 .1 ❑ UL508 S/N 1 .0 SUBMITTAL/JW 06/06/23 DRAWN RJC JOB N0. 81 1 3 ❑ S�N98A 1.1 RESUBMITTAL/JW 07/06/23 CITY OF PORT ORCHARD, WA DRTU 10-40.105A ❑ OTHER ti M Co Co >M z 0 w z 2 w 0 m (n ui 6L Q o W U w z o� Lo u � u UO C! Z O w Co O w oeo z C0 w � z z w 0 O = CD � U z J = (� w C/) Q Q _ 0- w w z = w > U Q Er ~ O w II. — cc z rr w p O _ �0- U J w Y— DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITEE TSI PUMP CONTROL DWG RTU-10-40.105B, RACK 1, SLOT 05—WIRING DIA SHT No 36 OF 39 BID SET 16-FEB-2024 p C— q4 RTU 1 0 FIELD (CONTINUED FROM DWG 40.105A) 8 Pt. 24VDC ANALOG OUTPUT MODULE FROM 24VDC UPS POWER DWG RTU 10-30.20 RACK 1 , SLOT 05 U24P U24C SPARE 1769-OF8C I OUT 4+ n A0.105.04+ � n (0.25A) DF.105.04 ANLG COM A0.105.04- 4-20mA A0.105.04-n SPARE I OUT 5+ n A0.105.05+ � n (0.25A) DF.105.05 ANLG COM A0.105.05- 4-20mA A0.105.05- �J SPARE I OUT 6+ n A0.105.06+ � n (0.25A) DF.105.06 ANLG COM A0.105.06- � 4-20mA A0.105.06- n SPARE I OUT 7+ n A0.105.07+ � n (0.25A) DF.105.07 ANLG COM A0.105.07- � 4-20mA A0.105.07- n U24P U24C REV DESCRIPTION/INIT DATE LISTING Technical Systems Inc. 2303 196TH sT. S.W. LYNNWOOD, WA. 98036 (425) 775-5696 CUSTOMER ART ANDERSON ASSOCIATES 8c EN / PM / CHK KD/AP/AP MELCHER BOOSTER PUMP STATION UPGRADE RTU 1 0 (RTU 1 0) ANALOG OUTPUT MODULE RACK 1 , SLOT 05 - WIRING DIAGRAM DATE CREATED 12/01 /2022 REV. 1 .1 ❑ UL508 S/N 1 .0 SUBMITTAL/JW 06/06/23 DRAWN RJC JOB N0. 81 1 3 ❑ S�N98A 1.1 RESUBMITTAL/JW 07/06/23 CITY OF PORT ORCHARD, WA DRTU 10-40.105B ❑ OTHER RTU 10 L:i MCK OFF I n HAND ! t AUTO \ CR.103.00 � - VFDO 1 -24C - - OOX OX 0 II n COX (CONT'D TO THIS SHEET RIGHT) SSM1 LOCAL SPEED CONTROL 3 10K0 2 n �J VFD01 —24V VFD01-24A VFDO1 -24D VFD01 -24E VFD01 -10VB r -� 1 1 VFD01-10VA I 1 1 1 �J DF.105.00_ _ _ DF.105.00_� 1 - - - - - - - - - - - - - - - - PLC ANALOG OUTPUT \ \ / (SEE DWG RTU 10-40.105A) AO.105.00- 4-2OmA AO.105.00- 1 +24V Dil VFD — M 1 VFD-M 1 (REF DWG RTU 10-30.01) +24 VOLT DC DIGITAL INPUT 0 DIGITAL INPUT 1 Di2 ❑ DIGITAL INPUT 2 D13 DIGITAL INPUT 3 Di4 ❑ DIGITAL INPUT 4 Di5 ❑ DIGITAL INPUT 5 DiC DIGITAL INPUT COMMON 24VC 4-1 24V COMMON + 1 OV +10 VOLT REFERENCE AiO+ 10VC T 10 VOLT COMMON AiO - Ai + ANALOG IN 1 + Ail - ANALOG IN 1 - SLOT 3 RUNNING (RO) SLOT 4 FAI L (R1) ROC RONO ROC RONO AoO+ ANALOG OUT 0+ Ao0- ANALOG OUT 0- VFD Parameters RTU 10 U24P I U24P D1.101.02--- n D1.101.02 SEE DWG 40.101 A D1.1 01 .03 n D1.101 .03 Al.104.00+_ _------------------- A1.104.00+� \ /' \ / PLC ANALOG INPUT I4-20mA_IA1.104.00- /�-/\------------------- A1.104.00 � (SEE DWG RTU10-40.104A) PAR # Description Value Units/Description PAR # Description Value Units/Description PAR # Description Value Units/Description PAR # Description Value Units/Description PORT 0 PORT 0 PORT 4 PORT 5 P26 Motor NIP Amps 52 Amps P550 Spd Ref B Sel PO4/PO6O P10 ROO Sel RO/1307 P5 Net Addr Src Parameters P28 Motor NIP RPM 1775 RPM P556 Jog Speed 1 55 Hz P45 Anlg in Type XX10 P7 IP Addr Cfg 1 192 P30 Motor NIP Power 40 Hp P62 Anlg In 1 Lo 4 mA P8 IP Addr Cfg 2 168 P150 Digital In Cfg 1 Run Level P70 Anlg Out Type XX11 P9 IP Addr Cfg 3 100 P155 DI Enable PO4/PO1/BOO Enable P75 Anlg OutO Sel 130001 P10 IP Addr Cfg 4 20 P163 DI Run PO4/PO1/BO1 Rijn Level P78 Anlg OutO DataHi 60 Hz P11 Subnet Cfg 1 255 P166 DI Jog PO4/P01/BO4 J g P81 Anlg OutO DataLo 4 mA P12 Subnet Cfg 2 255 P174 DI Speed Sel 1 PO4/P01/BO3 P13 Subnet Cfg 3 255 P230 ROO Sel P00/P935/1316 P14 Subnet Cfg 4 O P545 Spd Ref A Sel PO4/PO5O REV DESCRIPTION/INIT 1.0 SUBMITTAL/JW 1.1 RESUBMITTAL/JW DATE LISTING ❑ U L508 06/06/23 S/N 07/06/23 ❑ S/LN98A ❑ OTHER Technical Systems Inc. CUSTOMER EN / PM / CHK 2303 196TH ST. S.W. ART ANDERSON & KD/AP/AP LYNNWOOD, WA. 98036 ASSOCIATES DRAWN (425) 775-5696 RJC CITY OF PORT ORCHARD, WA MELCHER BOOSTER PUMP STATION UPGRADE MELCHER PUMP STATION RTU NO. 10 VFD CONTROL WIRING DIAGRAM DATE CREATED REV. 12/01 /2022 1.1 JOB NO. 8113 DWG. NO. RTU 1 0-50.01 ti M co co M >Q z 0 ry w 5 w 1Y m u U0 u UO v z O w � 0 w � z � a, � �z o LU =(.D < w = Q a Q � � 7) w o � za wLij w � a � O w w °C o O = U C/) 0 J W DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITLE TSI PUMP CONTROL DWG RTU-10-50.01, VPD CONTROL WIRING DIA BID SET 16—FEB-2024 SHT No 37 OF 39 "C-02t RTU 10 VFD02-24V HS-M2 CR-MCR u OFF 0d VFD02-24A HAND ! t � AUTO CR.103.01 VFD02-24C ^ n VFD02-24D OOX X00 n VFD02-24E OOX (CONT'D TO THIS SHEET RIGHT) SSM2 LOCAL SPEED CONTROL VFD02-10VB 3 10K0 I I VFD0210VA — — — — — — — — — — — — — — — — — — — 2 1 I VFDC2 1OVC — — — — — — — — — — — — — — — — — — — �J �J DF.105.01 _ _ DF.10_5.01_( 1 — — — — — — — — — — — — — — — — PLC ANALOG OUTPUT \ � \ / (SEE DWG RTU 10-40.105A) AO.105.01 - 4-2OmA AO.105.01 - 1 VFD-M2 VFD-M2 (REF DWG RTU 10-30.01) +24V SLOT 3 ROC +24 VOLT DC Di0 RUNNING RONO -❑ DIGITAL INPUT 0 �❑ Dil DIGITAL INPUT 1 MDIGITAL INPUT 2 D13 DIGITAL INPUT 3 Di4 ❑ DIGITAL INPUT 4 rD*5 DIGITAL INPUT 5 DiC DIGITAL INPUT COMMON 24VC 24V COMMON + 1 OV +10 VOLT REFERENCE AiO+ 1OVC 10 VOLT COMMON Ai0— Ai1 + -E ANALOG IN 1 + Ail - ANALOG IN 1 - U24P D1.102.02 SLOT 4 ROC FAIL RONO (R 1) n DI.102.03 RTU 10 U24P — — — n D1.102.02 n D1.102.03 SEE DWG 40.102A AoO+ 1A1.104.01+ _---------—A1.104_01+ ANALOG OUT 0+ �— A Ao0- I I \ / \ / PLC ANALOG INPUT I— A1.1 04.01 = / — / \ 4-20mA A1.1 04.01 -� (SEE DWG RTU 1 0-40.1 04A) ANALOG OUT 0- E]- — — — — — — — — — — — — — — — — — �J VFD Parameters PAR # Description Value Units/Description PAR # Description Value Units/Description PAR # Description Value Units/Description PAR # Description Value Units/Description PORT 0 PORT 0 PORT 4 PORT 5 P26 Motor NIP Amps 52 Amps P550 Spd Ref B Sel PO4/PO6O P10 ROO Sel RO/1307 P5 Net Addr Src Parameters P28 Motor NIP RPM 1775 RPM P556 Jog Speed 1 55 Hz P45 Anlg in Type XX10 P7 IP Addr Cfg 1 192 P30 Motor NIP Power 40 Hp P62 Anlg In 1 Lo 4 mA P8 IP Addr Cfg 2 168 P150 Digital In Cfg 1 Run Level P70 Anlg Out Type XX11 P9 IP Addr Cfg 3 100 P155 DI Enable PO4/P01/B00 Enable P75 Anlg OutO Sel 130001 P10 IP Addr Cfg 4 20 P163 DI Run PO4/PO1/BO1 Rijn Level P78 Anlg OutO DataHi 60 Hz P11 Subnet Cfg 1 255 P166 DI Jog PO4/P01/BO4 J g P81 Anlg OutO DataLo 4 mA P12 Subnet Cfg 2 255 P174 DI Speed Sel 1 PO4/P01/BO3 P13 Subnet Cfg 3 255 P230 ROO Sel P00/P935/1316 P14 Subnet Cfg 4 0 P545 Spd Ref A Sel PO4/PO5O REV I DESCRIPTION/INIT DATE 1.0 SUBMITTAL/JW 06/06/23 1.1 RESUBMITTAL/JW 07/06/23 LISTING ❑ U L508 S/N ❑ UL698A S/N ❑ OTHER Technical Systems Inc. CUSTOMER 2303 196TH ST. S.W. ART ANDERSON & LYNNWOOD, WA. 98036 ASSOCIATES (425) 775-5696 CITY OF PORT ORCHARD, WA EN / PM / CHK KD/AP/AP DRAWN RJC MELCHER BOOSTER PUMP STATION UPGRADE MELCHER PUMP STATION RTU NO. 10 VFD CONTROL WIRING DIAGRAM DATE CREATED REV. 12/01 /2022 1.1 JOB NO. 8113 DWG. NO. RTU 10-50.02 ti M co 00 M >Q z 0 ry w 75 w ry m Z 0 Cn w W w Z Q Q ago z O w � 0 w � z � a, � � z o LU =(.D < w = U) � Q a Q � � � w o � za w w � a rr � O w w °C o O = U C/) 0 J W DRAWN: --- DESIGNED: --- CHECKED: --- ISSUE DATE 2/16/2024 REVISIONS JOB NO FACP0017 SHT TITLE TSI PUMP CONTROL DWG RTU-10-50.02, VPD CONTROL WIRING DIA BID SET 16—FEB-2024 SHT No 38 OF 39 C-021 ti M co 00 >� W 10 Ata TE I'41%A WEA1 H ER H EAR z o ui TO4 HEAD END) w c. tL C E O Lu m Cl) ui 6L Q o W U L? Q U � w z do M W Q o -GROVNDINCP CABLE (NIMIWI-FM # ) ❑ a ❑ 2" CALVMIZEID RKAD - -' COND +IIr 115 t 1.- U 1 ET- i" x t, � F131 .' C'.ONDUIT LWN CELL ANTENNA (AUGN ALL ANTENNA N��F'LE TOSS NEAREST CELL TOWER) z W __ -- > co W ce) W C/) z C IAL CABLE - o� O 3FT. IuI"MUN `.ROUNDING CABLE z _ � (NINIhJLIM 08) U Z AUX CELL ANTENNA �.. _ H W = (AL GN CVL.L.. ANTENNA � i `T TOWARDS NDREST `•,., �� �ANIZEV I�Ir�I[� C/� � C/� Q = � CELL Tom) Q THREADED GRAYLAY - IR'C�f�l � GR�Uf�a �t `� _ � x i li �IaUIT W 0 TO KITH :STEEL COVER AND TO SET tdElui,4 3F� (;k-EX ET' F�-AT I hl��r �-- NffLE 0- H Q z APPLETON OAT JAPPTR67 WEATHERHEAD W W = - W > U Q Ir MINIh UIW - . AS" >- O W HIGHEST PW - - _ z "LiDiNG STRUCTURE COMAL CABLE = 0 O ---- U � � OUNDING ALE J ;.IMl Nlhl'UM 98) W 2" r ALVAt41ZFiD RH_;jD DRAWN: --- CMG�nr - DESIGNED: --- - LENGTH NEE O CHECKED: --- - ISSUE DATE D0T11E 2w RIGIDCONDUIT T WREAD'ED 2/16/2024 FLU FLANGE CAT #FF200 . -r•JT�Y L�E1� 8 ILDW CONTROL .ANG40R1EINTO CONC-FETE BASE. REVISIONS NOTES AS NEEDED 1. DO NOT INSTALL ANY I 'NEP CONIDUCTOPS- INSVC OF 00MM147 VOTH COAX ALES. JOB NO FACP0017 REV DESCRIPTION/INIT DATE LISTING Technical Systems Inc. CUSTOMER ART ANDERSON & EN / PM / CHK KD/AP/AP MELCHER BOOSTER PUMP STATION UPGRADE DATE CREATED 1 2/01 /2022 REV. 1 SHT TITLE UL508 1.0 SUBMITTAL/JW 06/06/23 ❑ S/N 2303 196TH ST. S.W. LYNNWOOD, WA. 98036 ASSOCIATES M E LC H ER PUMP STATION RTU NO. 10 .1 TSI PUMP CONTROL DRAWN JOB NO. UL698A ❑ S/N (425) 775-5696 RJC 8113 DWG RTU-10-99.01, ANTENNA INSTL DETAIL 1.1 RESUBMITTAL/JW 07/06/23 CITY OF PORT ORCHARD, WA ANTENNA INSTALLATION DETAIL DIAGRAM DWG. N0. RTU 1 0-99.01 DIA ❑ OTHER SHT No 39 01 39 BID SET 16—FEB-2024 PC-o2%.