Loading...
Site Plan_LU24-CUP-03GRAPHIC SCALE /?Jilyl III' Iil lil il!! I , _ - z-- MCCORMICK NORTH PHASE III - VILLAGE COMMERCIAL 0 60 120 ;/'j� �I 111 • 11 ///// I ` ; fi°6 ASP P ' A PORTION OF SECTION 4 & 5, TOWNSHIP 23N, RANGE 01 E, W.M., EMERGENCY 1 INCH = 60 FEET(22"x34")==1j�i. ///,,,l r/ OVERFLOW CITY OF PORT ORCHARD, KITSAP COUNTY, WASHINGTON / SPILLWAY30 YSF 1 INCH = 120 FEET (11"x17) //// EXISTING POND — f //'ii'// / INLET — —-------� / / / 02 '4�/ // / 50' ASSUMED STREAM BUFFER STEEP SLOPE SETBACK— /�/ co POND OUTFALL r a/ V / \ � N l \ OVERFLOW AND FLOW CONTROL STRUCTURE COMBINATION INFILTRATION/DETENTION POND RELOCATED POND INLET / 1 AU \ \\ EXISTING POND INLET / I �� � � / ��/ _ pE - �• - - -` - _TOE- �" _-_ .� oW f \\ \ •1 a �' RIP RAP } I w I \ CPI i 2zo � \ • IX TOP— � ........:.... _ S�-1 / — — — — ✓ / PRE-TREATMENT WATER SS QUALITY VAULT STORM POINT OF CONNECTION \ \S D —\ — ,I \ \ / TO EXISTING STORM SYSTEM sD 8" WATER MAIN FOR ALL PRE-TREATMENT WATER INTERNAL PLAT ROADS (TYP.) \ \ \ \ QUALITY VAULT 44, \\ J ! WCORMICK /1 / /M° VI LLAG E EAST - II WETLAND \� \ \i I \ / , / o_ PAD-433.0, WATER METER SERVICE (TYP.) / / \ 20' UTILITY SEWER SERVICE (I \ \ \ ~ J \ I RIGHT OF WAY LINE MCCORMICK VILLAGE WEST \ \\ \\ \\ ' /'} } \I \� \ 1 PAD=434.5 STUBS FOR WATER,SEWER, AND STORM FOR FUTURE USE {TYP.) �,o 436 I 143800 15' SEWER EASEMEI 1 1 I I I / McCORMICK 3 / DIVISION 2 / II \ WATER POINT OF CONNECTION TO EXISTING \ 8" `MAIN PIPE PAD=432.5 \ I PAD=431.5 RETAINING WALL AND FOOTING I I DRAINS TO BE ROUTED TO LOWER RKING STORM DRAIN SYSTEM Z PAD=432.5 ICK VILLAGE y COMMERCIAL �RLHYDRANT (TY COMMERCIAL DRIVE (PRIVATE — J �f�/ ,w 0 `J :MENT / �'� .Lr1, C/ 42Q GRAVITY SEWER POINT OF CONNECTION TO PAD=433.0 PAD=432.5 EXISTING 8" SEWER STUB / / , �jj. WALE TDE PROPOSED CONNECTION 1 1 1 / ,' / POINT TO EXISTING PAD-434.0 1 1 %{, ri / STORMWATER SYSTEM FOR 435.0 / J I ( LOWER PARKING AREA / 1 ` \ b RIGHT OF LANE / PROPERTY LINE 9 RETAINING WALL TO BE DESIGNED AND 1 I I / Z4 �, PERMITTED WITH ASSOCIATED BUILDING PERMIT. FOOTING DRAIN TIED TO STUB PROVIDED. RETAINING WALL AND FOOTING DRAIN SHALL DAYLIGHT TO EXISTING GRADE V, STRIPPING QUANTITIES STRIPPING DEPTH ASSUMED = 9" STRIPPING VOLUME = 19,900 C.Y. 1. THIS CALCULATION IS FOR REVIEW AND PERMITTING PURPOSES ONLY. THE NUMBERS SHOWN ARE GENERATED FROM THE EXISTING GROUND SURFACE 2. STRIPPING DEPTH IS ASSUMED AT THIS TIME, NO GEOTECHNICAL RECOMMENDATION FOR THE STRIPPING DEPTH HAS BEEN DONE AT THE TIME OF THIS CALCULATION. GRADING QUANTITIES CUT = 61,115 CU YDf FILL = 34,600 CU YDf NET = 26.515 CU YDf CUT THIS CALCULATION IS FOR REVIEW AND PERMITTING PURPOSES ONLY. THE NUMBERS SHOWN ARE GENERATED FROM THE FINISHED GROUND SURFACE (I.E. TOP OF PAVEMENT, TOP OF CONCRETE, TOP OF PAD, ETC.) TO THE ASSUMED STRIPPED EXISTING GROUND SURFACE AS NOTED ABOVE. CONTRACTOR SHALL DO THEIR OWN CALCULATION BASED ON THE INFORMATION PROVIDED WITHIN THESE PLANS. THE QUANTITIES MAY VARY BASED ON THE FOLLOWING FACTORS: 1. SHRINK/SWELL OF EXISTING SOILS 2. VARIANCE OF VEGETATION THICKNESS AND UNSUITABLE TOPSOIL 3. SUBBASE REQUIREMENTS FOR THE ROAD SECTIONS 4. SUBBASE REQUIREMENTS FOR THE BUILDING FOUNDATION BASED ON THE FINAL STRUCTURAL DESIGN 5. TRENCHING EXCAVATION FOR PROPOSED UTILITIES 6. ADDITIONAL CUT/FILL MAY BE REQUIRED FOR FUTURE UTILIZATION OF THE SITE 7. SOME AREAS OF THE SITE HAVE ALREADY BEEN STRIPPED FROM PERVIOUS PHASES OF DEVELOPMENT, THESE AREAS ARE ACCOUNTED FOR INTHE GRADING QUANTITIES NOTED ABOVE, BUT HAVE NOT BEEN VERIFIED BY A LICENSED SURVEYOR. This submittal has been reviewed by The City of Port Orchard and is APPROVED NOT APPROVED due to �. 12/ 19/2023 ame Date VERIFICATION NOTE ALL EXISTING UTILITIES IN THE CONSTRUCTION AREA SHALL BE IDENTIFIED AND VERIFIED FOR DEPTH AND LOCATION PRIOR TO ANY CONSTRUCTION ACTIVITIES SO TO IDENTIFY ANY POTENTIAL CONFLICTS WITH PROPOSED CONSTRUCTION. CONTACT PROJECT ENGINEER IMMEDIATELY IF ANY CONFLICTS ARE IDENTIFIED. PRIOR TO ANY CONSTRUCTION ACTIVITIES, VERIFY EXISTING TOPOGRAPHY IS CONSISTENT WITH WHAT IS SHOWN ON PLANS AND IF THERE ARE ANY POTENTIAL CONFLICTS WITH PROPOSED CONSTRUCTION ACTIVITIES. CONTACT PROJECT ENGINEER IMMEDIATELY IF ANY CONFLICTS ARE IDENTIFIED. CALL 811 AT LEAST 48 HOURS BEFORE YOU DIG m= M Q � o c� Z w< o" Qw O z� a � ow U) � a U� 0 C) LLJ z � og a� zp w� �w z O W w V � m rong JLuo M U JZQL� � M L a000-0 C M L Z 2 —zzI-C) =oLDto W0���Nt LU TM z LU > LI) x 4.1 z=xocV) u� � a L 2 n Q� � M Lin 0 w^ate Z LU L:2 C LU Lrj F � y N -d LLI U iY F . �r S NA 27 No ember 2023 0 0 00 J g � 0 LU I z Q o Lij (D Q z o z J_ U o Q i J C) z - N Ww w � F- V Q a Z Ln M J J LU o 00 LU O Q M ca z m �z� Q J LU Y Ego Y > ~ M Y � W 0 0o 6 , U U C5 U' Z.o3Y U W W z z W z CIO U U DESIGNER: M. GOULARTE ENGINEER: J. HAUG DRAWN: A. KING S4&5 T23 N R01E WM DATE: 16 May 2023 REVISED: 27 November 2023 PROJECT: 22-017 DWG NAME: 22-017 C SHEET REV. CIO 11 OF 50 LU24-CUP-03