Loading...
HomeMy WebLinkAboutAbove Ground Pool Barrier Option Submittal Form 2021 CodesCITY OF PORT ORCHARD DEPARTMENT OF COMMUNITY DEVELOPMENT RESIDENTIAL ONGROUND STORABLE POOL APPLICATION BARRIER OPTIONS SUBMITTAL FORM This form is designed to streamline the application, plan review, and inspection process for on -ground storable residential pools by using option sheets and ready -to -use details. Construction plans that contain adequate drawings, notes and details to demonstrate that minimum code requirements are met can be used in lieu of this form. This form, if used, must be filled out and submitted with the permit application and will be reviewed. All pages must be included. These details are not approved for construction unless stamped approved by City plan reviewer at the bottom of each page. In addition to this form, the applicant must include a site -specific site plan. See Site Plan Checklist for a full list: https://portorchardwa.gov/documents/form-085-site-plan-checklist/ If pool barrier fence is located in a yard setback, consult with Planning unit for Fence Design Standards, which limits some fence options. To use this form: 1. Check the box for which option will be used for the pool barrier type: Figure 1, Figure 3, Figure 4, or Figure 12. 2. If selecting Figure 3 or 4, choose between Figures 5 - 11 for the fence type. 3. If selecting Figure 4, check the box for Figure 13 if it applies to the project. Leave unchecked if it does not apply to the project. 4. Select between Figures 14-17 for which steps/ladder type will be used 5. Select Figure 19 if pool includes a pre -manufactured deck. Refer to the 2021 International Swimming Pool and Spa Code for all requirements. Available for free reading here: https://codes.iccsafe.org/content/ISPSC2021 P3 Applicant Name: Site Address: 'I I Cover NOT VALID FOR CONSTRUCTION UNLESS INSTRUCTIONS --- STAMPED APPROVED BY CITY: Permit: City of Port Orchard Based on the 2021 International Swimming Pool and Spa Code Barrier Options Submittal Form Revised 6/26/25 WHEN NOT IN USE, LADDER OR STEPS MUST BE CAPABLE OF 48" MINIMUM BEING SECURED IN THE UPRIGHT HEIGHT AROUND POSITION ABOVE THE 48" LEVEL, PERIMETER OR LOCKED OR REMOVED TO POOL PREVENT ACCESS INTO THE POOL GRADE POOL 48" OR MORE IN HEIGHT Check box if using FIGURE 1 - ABOVEGROUND POOL WALL IS USED AS BARRIER this option �❑ MEASURE 3FT HORIZONTALLY OUT 48"MIN HEIGHT -' GRADE POOL GRADE FIGURE 2 - FENCE ON SLOPING GROUND OPENINGS CANNOT ALLOW PASSAGE OF 4" SPHERE I - 48" MINIMUM HEIGHT 4" MAX GO TO PAGE 2 AND 3 TO _____.r CLEARANCE POOL POST SELECT FENCE TYPE CANNOT USE MESH FENCE GRADE WITH THIS OPTION Check box if using POOL LESS THAN 48" HEIGHT this option ❑ FIGURE 3- ABOVE GROUND POOL WITH FENCE ON TOP OF POOL WALL OPENINGS CANNOT ALLOW PASSAGE OF4"SPHERE 48" MIN FINISHED FROM GRADE* GRADE FIGURE 4 -POOL BARRIER: FENCES ON GRADE GO TO PAGE 2 AND 3 TO Z2 -MAX FROM GRADE SELECT FENCE TYPE 4" MAX FROM SOLID SURFACE (CONCRETE/PAVERS) Check box if using "FENCES IN A FRONT YARD SETBACK ARE LIMITED TO A HEIGHT OF 48" AND MUST BE MIN 38% OPEN. this option IN NO INSTANCE MAY A FENCE WITHIN A YARD SETBACK EXCEED 6FT. CONSTRUCTION PLANS WILL BE REQUIRED FOR FENCES OVER 6FT NOT LOCATED IN A SETBACK. Site Address: Pg 1 BARRIER TYPES NOT VALID FOR CONSTRUCTION UNLESS _-� STAMPED APPROVED BY CITY: Permit: City of Port Orchard Based on the 2021 International Swimming Pool and Spa Code Barrier Options Submittal Form Revised 6/26/25 HORIZONTAL 4" MAX. HORIZONTAL 1-3/4" MAX. MEMBER TOWARDS POOL -7 OPENING [.-(TYPICAL) MEMBER TOWARDS OPENING POOL (TYPICAL) POST POST w O O v V N -J N OO V I GRADE GRADE FIGURE 5- PICKET FENCE FIGURE 6- PICKET FENCE (HORIZONTAL MEMBERS 45" OR MORE APART) (HORIZONTAL MEMBERS LESS THAN 45" APART) Check box if using LI1Check this option box if using I this option APPROVED WIRE MESH ON FIGURE 9 - GATE HORIZONTAL OUTSIDE. MAX. HORIZONTAL MEMBER TOWARDS 1-3/4" INCH OPENING 1-3/4". (2" c/c 18" 18" POOL MAXIMUM OPENING SPACING). INSTALLED PER FG. INSTRUCTIONS. 1/2" MAX. POST OPENING H LATCH ________ RELEASE E Z (POOL IL SIDE)* X '• X. Q ; N 00 GRADE ` Check box if using a *IF GRADE Mesh must be vinyl or PVC to meet Planning design standards LATCH :OPENS AWAY! RELEASE IS NOT gate FROM POOL FIGURE 7 FIGURE 8 ,: ON POOL SIDE, ❑ MUST BE PLACC ED ; ::'� ❑ CHAIN LINK MESH FENCE MIN 54" HIGH •.................: GATES SHALL HAVE A SELF -LATCHING, SELF -CLOSING Check box if using Check box if using DEVICE LOCATED INSIDE THE POOL AREA. this option this option BARRIER ALARMS WHERE REQUIRED SHALL BE LISTED & LABELED AS A WATER HAZARD ENTRANCE ALARM IN ACCORDANCE WITH UL 2017. Site Address: Pg 2 • + BARRIER TYPES NOT VALID FOR CONSTRUCTION UNLESS Permit: STAMPED APPROVED BY CITY: City of Port Orchard Based on the 2021 International Swimming Pool and Spa Code Barrier Options Submittal Form Revised 6/26/25 1-3/4" MAX OPENING 45 DEGREES MAX FROM BETWEEN DIAGONALS VERTICAL FIGURE 10- DIAGONAL MEMBERS Check box if using this option O MUST COMPLY WITH ASTM F1346 SEPARATE ELECTRICAL PERMITS THROUGH WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES WALL CANNOT HAVE PROTRUSIONS OR INDENTATIONS THAT FORM HANDHOLDS/FOOTHOLDS • d .'.. Q• fl,.4.. . Q• D', p .. p.. .'• A.. •' D .. d d Q 4 , 00 FIGURE 11 - FREESTANDING SOLID WALL* Check box if using this option *CONSTRUCTION PLANS REQUIRED FOR FREESTANDING WALLS OVER 6FT Grade NOT COMPATIBLE WITH MOST ABOVEGROUND STORABLE POOLS FIGURE 12 POWERED SAFETY COVER BARRIER FENCE DRAW IN AND POOL LABEL DOORS AND/OR WINDOWS THAT OPEN INTO POOL AREA ON SEPARATE SITE PLAN HOUSE INCLUDE MANUFACTURER'S SPECS WITH SUBMITTAL Check box if using this option FIGURE 13 HOUSE WALL AS BARRIER ALL DOORS AND ALL WINDOWS THAT ARE LESS THAN 48" FROM FLOOR TO SILL MUST HAVE UL 2017 LISTED AUDIBLE ALARMS. DEACTIVATION SWITCH MUST BE 48" - 54" ABOVE THE FLOOR. Check box if using this option INCLUDE MANUFACTURER'S SPECS WITH SUBMITTAL Site Address: Pg 3 _ ^• ' '" •,� NOT VALID FOR CONSTRUCTION UNLESS BARRIER TYPES STAMPED APPROVED BY CITY: Permit: CI yf rPort Orchard Based on the 2021 International Swimming Pool and Spa Code Barrier Options Submittal Form Revised 6/26/25 Select which ladder/steps will be used. Include manufacturer's specs with submittal. FIGURE 14 A box it using this type ❑ TYPES A AND B •If A frame ladder has platform between handrails, min 12" width, min 12" length. •Platform must be at or above highest ladder tread — made with slip resistant material. •Must have two handrails that serve all treads, min 20" above upper most tread/platform. 1" — 1.9" diameter for handrail •Min 12" clear distance between handrails •Min 2" tread depth for ladder treads •Risers must be at uniform height min 7" max 12" FIGURE 1 r'",nr'L' hox if using this type TYPE C •Type C staircase ladders need minimum 2 handrails, min 20" above platform/top tread •1"-1.9" handrail diameter •Ladder treads horizontal uniform tread depth min 4" •Riser height to be min 7" max 12" uniform height. The vertical distance from the platform/top of pool to the uppermost tread must be same as uniform riser heights •Top step must be flush with the deck or 7"-12" below the deck level •Min 19" clear distance between side rails, unobstructed FIGURE 16 Check box if using f I FIGURE 17 Check box if using this type this type TYPE D •Clearance of min 3" max 6" between pool wall and the ladder •Min 2 handrails min 20" above platform/deck •Min 12" clear distance between handrails •1" — 1.9" handrail diameter •Riser height to be min 7" max 12" uniform height. •Vertical distance from pool coping, deck, or step surface to top tread must be mi 7" and max 12" and uniform with other risers •Min 2" tread depth TYPE E and F •Must have at least one handrail that serves all treads min 20" above top tread/platform •If handrails are removable, must be installed so they cannot be removed without use of tools •Leaning edge of handrails must be 18" horizontally from vertical plane of bottom riser •1" — 1.9" handrail diameter •Treads must have horizontal unobstructed depth min 10" and min 240 square inch surface area •Riser height to be min 7" max 12" uniform height. I Site Address: Pg 4 _ NOT VALID FOR CONSTRUCTION UNLESS LADDERS/STEPS +� STAMPED APPROVED BY CITY: Permit: I Cit1 Port Orchard Based on the 2021 International Swimming Pool and Spa Code Barrier Options Submittal Form Revised 6/26/25 MIN 36" FROM BARRIER TO PERMANENT STRUCTURES OR EQUIPMENT OUTSIDE THE POOL AREA FIGURE 18 - GENERAL PERIMETER BARRIER REQUIREMENTS PLAN VIEW CHECK SURFAL -15 INCHES MIN - 1 POOL WALL STRUC' DECK SURFACE 15 INCHES MINI 1 INCH MAX ALL GAPS MUST BE CLOSED -OFF OR CAPPED. • 3 INCHES MAX POOL WALL STRUCTURE CANTILEVERED DECK SUPPORT FLUSH DECK DECKS CONSTRUCTED ON SITE REQUIRE DECK CONSTRUCTION PLANS* FIGURE 19 - MANUFACTURED DECKS MUST BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. *POOLS SUPPORTED ON PROVIDE SPECS WITH SUBMITTAL. A DECK WILL REQUIRE PLANS STAMPED BY A Check box if using a ❑ WASHINGTON LICENSED pre -manufactured deck REGISTRANT Site Address: Pg5 ..� NOT VALID FOR CONSTRUCTION UNLESS BARRIER LAYOUT & DECKS STAMPED APPROVED BY CITY: Permit: City of Port Orchard Based on the 2021 International Swimming Pool and Spa Code Barrier Options Submittal Form Revised 6/26/25